The American journal of cardiology · 2015
Effectiveness and Safety of Transcatheter Closure of Perimembranous Ventricular Septal Defects in Adults.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Jianming, Zuo Jian, Yu Shiqiang, Yi Dinghua, Yang Xiuling, Zhu Xianyang, Li Jun, Yang Lifang, Xiong Lize, Ge Shuping, Ren Jun, Yang Jian
Аннотация
This study was designed to determine the long-term safety and efficacy of using modified double-disk occluders for perimembranous ventricular septal defect (pmVSD) closure in adults. From January 2004 to December 2014, 337 adults with pmVSDs were treated through transcatheter intervention using 2 types of double-disk occluders; 302 patients received a symmetrical concentric pmVSD occluder, and 35 patients received an asymmetrical concentric pmVSD occluder. All patients were followed up through electrocardiography and transthoracic echocardiography until June 2015. The success rate was 100% for both procedures. During the median 71-month follow-up period, no cases of infective endocarditis, cerebrovascular accidents, heart failure, or death occurred. Two major adverse events (0.6%) were recorded: complete atrioventricular block requiring surgical treatment in one patient and severe tricuspid valvular regurgitation requiring surgical repair in another patient. Cardiac conduction block was the most common minor adverse event. The mean left ventricular (LV) end-diastolic volume decreased from 96.6 ± 23.2 ml before intervention to 86.0 ± 22.0 ml (p <0.05) at the 6-month follow-up visit. Previously enlarged LV chambers decreased to normal sizes during the follow-up period. In conclusion, transcatheter closure of pmVSDs using modified double-disk occluders was both safe and effective and yielded excellent long-term results in adults. The potential benefits of this intervention included remodeling of the heart, a reduced incidence of infective endocarditis and prevention of LV volume overload.
Предметные рубрики MeSH
AdolescentAdultAgedAtrioventricular BlockCardiac CatheterizationEchocardiographyFemaleFollow-Up StudiesHeart Septal Defects, VentricularHumansKaplan-Meier EstimateMaleMiddle AgedPatient SafetyProsthesis DesignRetrospective StudiesRisk AssessmentRisk FactorsSeptal Occluder DeviceTime FactorsTreatment OutcomeTricuspid Valve Insufficiency