Use of pre-intervention imaging with a novel image fusion software for guidance of cardiac catheterisation in a patient with pulmonary atresia and major aortopulmonary collaterals.
Аннотация
We present a 3.5-year-old patient with tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collaterals, after repeat implantation of a central shunt, in whom we successfully re-purposed previous imaging scans with a novel image fusion software to guide diagnostic heart catheterisation. The pre-registered CT scan was segmented before the procedure and subsequently manually fused with two-dimensional fluoroscopy images. The overlaid roadmap enhanced selective cannulation of all major vessels originating from the aorta, making aortography unnecessary.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.