Does providing atrial fibrillation patients, after pulmonary vein isolation, with a 1-lead ECG device relieve the emergency department?-A historically controlled prospective trial.

Selder Jasper L, Mulder Mark J, van de Vijver Willem R, Croon Philip M, Wentrup Leontine E, van der Pas Stéphanie L, Twisk Jos W R, Tulevski Igor I, Van Rossum Albert C, Allaart Cornelis P

СтатьяПеревод в очереди

Аннотация

UNLABELLED: Atrial fibrillation (AF) is a prevalent and clinically significant cardiac arrhythmia, with a growing incidence. The primary objectives in AF management are symptom relief, stroke risk reduction, and prevention of tachycardia-induced cardiomyopathy. Two key strategies for rhythm control include antiarrhythmic drug therapy and pulmonary vein isolation (PVI), with PVI being recommended for selected patients. Even though PVI is effective, post procedural health care utilization is high, contributing to emergency department (ED) overcrowding, which is a global healthcare concern. The use of remote rhythm diagnostics, such as a 1-lead ECG device (KM), may mitigate this issue by reducing ED visits and facilitating more plannable AF care.

OBJECTIVE

This study aimed to assess whether providing AF patients with a 1-lead ECG device for 1 year after PVI would reduce ED utilization compared to standard care. Additionally, the study assessed whether this intervention would render AF care more plannable by reducing the incidence of unplanned cardioversions.

METHODS

A historically controlled, prospective clinical trial was conducted. The intervention group were patients undergoing PVI for AF between September 2018 and August 2020, all patients in this group received a 1-lead ECG device for 1 year for remote rhythm monitoring. The historical control group were patients undergoing PVI between January 2016 and December 2017; these patients did not receive a 1-lead ECG device. Data on ED visits, planned and unplanned cardioversions, and outpatient contacts in the year after the PVI were collected for both groups.

RESULTS

The study included 204 patients, 123 in the 1-lead ECG group and 81 in the standard care group. There was no statistically significant difference in the number of all-cause ED visits (63 vs 68 per 100 pts, respectively, p = 0.72), ED visits for possible rhythm disorders, or ED visits for definite rhythm disorders between the two groups. However, the 1-lead ECG group demonstrated a higher proportion of planned cardioversions compared to unplanned ones (odds ratio 4.9 [1.57-15.85], p = 0.007).

CONCLUSION

Providing patients with AF following PVI with a 1-lead ECG device did not result in a statistically significant reduction in ED visits during the first year. However, it did improve the management of recurrent AF episodes by substituting unplanned cardioversions with scheduled ones. Clinical Trials Registration Number NCT06283654.

Для цитирования: Selder Jasper L, Mulder Mark J, van de Vijver Willem R, Croon Philip M, Wentrup Leontine E, van der Pas Stéphanie L, Twisk Jos W R, Tulevski Igor I, Van Rossum Albert C, Allaart Cornelis P. Does providing atrial fibrillation patients, after pulmonary vein isolation, with a 1-lead ECG device relieve the emergency department?-A historically controlled prospective trial.. PLOS digital health. 2024. DOI: 10.1371/journal.pdig.0000688.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.