DOI 10.1046/j.1464-410x.1999.00246.x
Failure of allograft suburethral slings.
Аннотация
OBJECTIVES
To report our experience of using freeze-dried irradiated fascia lata allografts for suburethral sling procedures.
PATIENTS AND
METHODS
Between December 1996 and September 1998, 35 patients (mean age 60.25 years, range 37-79) underwent suburethral sling placement with fascia allograft. These patients were reviewed, with the findings at the time of any surgical re-exploration. Eleven (31%) had undergone prior surgery for genuine stress incontinence and 32 (91%) had a preoperative diagnosis of intrinsic sphincter deficiency.
RESULTS
On re-operation for persistent or recurrent stress incontinence, the allograft was present but grossly degenerated in two (6%) patients and completely absent in five (14%) patients. Histology of a retrieved graft fragment showed both fibroblast proliferation and degeneration within the graft.
CONCLUSION
The use of freeze-dried, irradiated fascia lata for suburethral sling procedures was associated with a material failure rate of >/=20%. We caution against its use in this setting.