Machine Learning Model for Classifying the Results of Fetal Cardiotocography Conducted in High-Risk Pregnancies.

Park Tae Jun, Chang Hye Jin, Choi Byung Jin, Jung Jung Ah, Kang Seongwoo, Yoon Seokyoung, Kim Miran, Yoon Dukyong

СтатьяПеревод в очереди

Аннотация

PURPOSE: Fetal well-being is usually assessed via fetal heart rate (FHR) monitoring during the antepartum period. However, the interpretation of FHR is a complex and subjective process with low reliability. This study developed a machine learning model that can classify fetal cardiotocography results as normal or abnormal.

MATERIALS AND

METHODS

In total, 17492 fetal cardiotocography results were obtained from Ajou University Hospital and 100 fetal cardiotocography results from Czech Technical University and University Hospital in Brno. Board-certified physicians then reviewed the fetal cardiotocography results and labeled 1456 of them as gold-standard; these results were used to train and validate the model. The remaining results were used to validate the clinical effectiveness of the model with the actual outcome.

RESULTS

In a test dataset, our model achieved an area under the receiver operating characteristic curve (AUROC) of 0.89 and area under the precision-recall curve (AUPRC) of 0.73 in an internal validation dataset. An average AUROC of 0.73 and average AUPRC of 0.40 were achieved in the external validation dataset. Fetus abnormality score, as calculated from the continuous fetal cardiotocography results, was significantly associated with actual clinical outcomes [intrauterine growth restriction: odds ratio, 3.626 (p=0.031); Apgar score 1 min: odds ratio, 9.523 (p<0.001), Apgar score 5 min: odds ratio, 11.49 (p=0.001), and fetal distress: odds ratio, 23.09 (p<0.001)].

CONCLUSION

The machine learning model developed in this study showed precision in classifying FHR signals. This suggests that the model can be applied to medical devices as a screening tool for monitoring fetal status.

Для цитирования: Park Tae Jun, Chang Hye Jin, Choi Byung Jin, Jung Jung Ah, Kang Seongwoo, Yoon Seokyoung, Kim Miran, Yoon Dukyong. Machine Learning Model for Classifying the Results of Fetal Cardiotocography Conducted in High-Risk Pregnancies.. Yonsei medical journal. 2022. DOI: 10.3349/ymj.2022.63.7.692.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.