A comparison of high-frequency jet ventilation and synchronised intermittent mandatory ventilation in preterm lambs.
Аннотация
PURPOSE: Synchronised intermittent mandatory ventilation (SIMV) and high-frequency jet ventilation (HFJV) are accepted ventilatory strategies for treatment of respiratory distress syndrome (RDS) in preterm babies. We hypothesised that SIMV and HFJV both facilitate adequate oxygenation and ventilation but that HFJV is associated with less lung injury.
RESULTS
There were no differences in arterial oxygenation or partial pressure of carbon dioxide despite lower mean airway pressure during SIMV for most of the study. There were no consistent significant differences in end systolic and end diastolic PBF, lung injury data and static lung compliance.
METHODS
Preterm lambs of anaesthetised ewes were instrumented, intubated and delivered by caesarean section after intratracheal suction and instillation of surfactant. Each lamb was managed for 3 hr according to a predetermined algorithm for ventilatory support consistent with open lung ventilation. Pulmonary blood flow (PBF) was measured continuously and pulsatility index was calculated. Ventilatory parameters were recorded and arterial blood gases were measured at intervals. At postmortem, in situ pressure-volume deflation curves were recorded, and bronchoalveolar lavage fluid and lung tissue were obtained to assess inflammation.
CONCLUSIONS
SIMV and HFJV have comparable clinical efficacy and ventilator pressure requirements when applied with a targeted lung volume recruitment strategy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.