Effects of arm elevation on radial artery pressure: a new method to distinguish hypovolemic shock and septic shock from hypotension.

Xie Zhiyi, Zhang Zhenyu, Xu Yuan, Zhou Hua, Wu Sheng, Wang Zhong

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

In this prospective observational study, we investigated the variability in radial artery invasive blood pressure associated with arm elevation in patients with different hemodynamic types.

PATIENTS AND

METHODS

We carried out a prospective observational study using data from 73 general anesthesia hepatobiliary postoperative adult patients admitted to an ICU over a 1-year period. A standard procedure was used for the arm elevation test. The value of invasive radial arterial pressure was recorded at baseline, and 30 and 60 s after the arm had been raised from 0° to 90°. We compared the blood pressure before versus after arm elevation, and between hemodynamically stable, hypovolemic shock, and septic shock patient groups.

RESULTS

In all 73 patients, systolic arterial pressure (SAP) decreased, diastolic arterial pressure (DAP) increased, and pulse pressure (PP) decreased at 30 and 60 s after arm elevation (P<0.01), but the mean arterial pressure (MAP) was unchanged (P>0.05). On comparing 30 and 60 s, there was no significant difference in SAP, DAP, PP, or MAP (P>0.05). In 40 hemodynamically stable patients, SAP and PP decreased, and DAP and MAP increased significantly at 30 and 60 s after arm elevation compared with baseline (P<0.01). In 16 hypovolemic patients, SAP, DAP, and MAP increased significantly compared with baseline at 30 and 60 s (P<0.01), but PP was unchanged (P>0.05). In 17 patients with septic shock, SAP, PP, and MAP decreased significantly versus baseline at 30 and 60 s (P<0.01), but DAP was unchanged (P>0.05). Comparison of the absolute value of pressure change of septic shock patients at 30 s after raising the arm showed that SAP, DAP, and MAP changes were significantly lower compared with those in hypovolemic shock and hemodynamically stable patients (P<0.01). The areas under the receiver operator characteristic curve for predicting septic shock was 0.930 [95% confidence interval (CI): 0.867-0.992, P< 0.001] for change value at 30 s after arm elevation of SAP. The best cut-off point for the SAP change value was -5 mmHg or less, with a sensitivity of 94.12%, a specificity of 80.36%, a positive likelihood ratio of 4.79 (95% CI: 2.8-8.2), and a negative likelihood ratio of 0.073 (95% CI: 0.01-0.5).

CONCLUSION

Our study shows that hypovolemic shock and septic shock patients have significantly different radial artery invasive blood pressure changes in an arm elevation test, which could be applied as a new method to distinguish hypovolemic shock and septic shock from hypotension.

Для цитирования: Xie Zhiyi, Zhang Zhenyu, Xu Yuan, Zhou Hua, Wu Sheng, Wang Zhong. Effects of arm elevation on radial artery pressure: a new method to distinguish hypovolemic shock and septic shock from hypotension.. Blood pressure monitoring. 2018. DOI: 10.1097/mbp.0000000000000318.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.