MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvs.2020.12.093

Медицинская библиотека · Journal of vascular surgery · 2021

Respiratory-induced changes in renovisceral branch vessel morphology after fenestrated thoracoabdominal aneurysm repair with the BeGraft balloon-expandable covered stent.

Tran Kenneth, Suh Ga-Young, Mougin Justine, Haulon Stephan, Cheng Christopher

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We evaluated the respiratory-induced changes in branch vessel geometry after thoracoabdominal fenestrated endovascular aneurysm repair (fEVAR) with the Bentley BeGraft graft (Innomed GmbH, Hechingen, Germany) as the covered bridging stent.

METHODS

Patients treated with fEVAR for thoracoabdominal aortic aneurysms with a custom-made Zenith fenestrated endograft (Cook Medical Europe Ltd, Limerick, Ireland) and Bentley BeGraft peripheral stents were prospectively recruited. Using SimVascular software (Open-Source Medical Software Corp, San Diego, CA), the pre- and postoperative aortic and branch contours were segmented from computed tomography angiograms performed during inspiratory and expiratory breath-holds. The centerlines were extracted from the lumen contours, from which the branch take-off angles, distal stent angles, and peak branch curvature changes were computed. Paired, two-tailed t tests were performed to compare the pre- and postoperative deformations.

RESULTS

Renovisceral vessel geometry was evaluated in 12 patients undergoing fEVAR with a total of 46 target vessels (10 celiac arteries, 12 superior mesenteric arteries [SMAs], 24 renal arteries). Implantation of BeGraft bridging stents was associated with a significant reduction in respiration-induced changes in vessel branch angulation (Δ5.3° ± 3.9° vs Δ12.0° ± 8.3° [postoperative vs preoperative]; P = .001) and mean curvature (0.72 ± 0.22 cm-1 vs 0.53 ± 0.18 cm-1) in the renal arteries, without significant changes in the celiac arteries or SMAs. No significant difference was found in end-stent angle motion in the renal arteries (P = .77), celiac arteries (P = .34), or SMAs (P = .55). The maximum local vessel curvature change decreased after fEVAR in the SMAs (Δ0.28 cm-1 vs Δ0.47 cm-1; P = .04) but was unchanged in the celiac (P = .61) and renal (P = .51) arteries.

CONCLUSIONS

Implantation of the BeGraft as a bridging stent in fEVAR was associated with decreased respiratory-induced deformation in the renal branch take-off angulation and mean renal artery curvature, with reduced maximum curvature bending in the SMA compared with the preoperative anatomy. However, the BeGraft allowed for celiac and renal artery bending similar to that in the native preoperative state. These findings suggest that the use of BeGraft peripheral stents with fEVAR will closely mimic the native arterial branch geometry and vessel conformability caused by relatively aggressive respiratory motion.

Для цитирования: Tran Kenneth, Suh Ga-Young, Mougin Justine, Haulon Stephan, Cheng Christopher. Respiratory-induced changes in renovisceral branch vessel morphology after fenestrated thoracoabdominal aneurysm repair with the BeGraft balloon-expandable covered stent.. Journal of vascular surgery. 2021. DOI: 10.1016/j.jvs.2020.12.093.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.