The European respiratory journal · 2021

Dyspnoea and respiratory muscle ultrasound to predict extubation failure.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dres Martin, Similowski Thomas, Goligher Ewan C, Pham Tai, Sergenyuk Liliya, Telias Irene, Grieco Domenico Luca, Ouechani Wissale, Junhasavasdikul Detajin, Sklar Michael C, Damiani L Felipe, Melo Luana, Santis Cesar, Degravi Lauriane, Decavèle Maxens, Brochard Laurent, Demoule Alexandre

Аннотация

BACKGROUND: This study investigated dyspnoea intensity and respiratory muscle ultrasound early after extubation to predict extubation failure.

METHODS: The study was conducted prospectively in two intensive care units in France and Canada. Patients intubated for at least 48 h were studied within 2 h after an extubation following a successful spontaneous breathing trial. Dyspnoea was evaluated by a dyspnoea visual analogue scale (Dyspnoea-VAS) ranging from 0 to 10 and the Intensive Care Respiratory Distress Observational Scale (IC-RDOS). The ultrasound thickening fraction of the parasternal intercostal and the diaphragm was measured; limb muscle strength was evaluated using the Medical Research Council (MRC) score (range 0-60).

RESULTS: Extubation failure occurred in 21 out of 122 enrolled patients (17%). The median (interquartile range (IQR)) Dyspnoea-VAS and IC-RDOS were higher in patients with extubation failure versus success: 7 (4-9) versus 3 (1-5) (p<0.001) and 3.7 (1.8-5.8) versus 1.7 (1.5-2.1) (p<0.001), respectively. The median (IQR) ratio of parasternal intercostal muscle to diaphragm thickening fraction was significantly higher and MRC was lower in patients with extubation failure compared with extubation success: 0.9 (0.4-2.1) versus 0.3 (0.2-0.5) (p<0.001) and 45 (36-50) versus 52 (44-60) (p=0.012), respectively. The thickening fraction of the parasternal intercostal and its ratio to diaphragm thickening showed the highest area under the receiver operating characteristic curve (AUC) for an early prediction of extubation failure (0.81). AUCs of Dyspnoea-VAS and IC-RDOS reached 0.78 and 0.74, respectively.

CONCLUSIONS: Respiratory muscle ultrasound and dyspnoea measured within 2 h after extubation predict subsequent extubation failure.

Предметные рубрики MeSH