DOI 10.1111/apa.12998

Медицинская библиотека · Acta paediatrica (Oslo, Norway : 1992) · 2015

High-flow nasal cannulae are associated with increased diaphragm activation compared with nasal continuous positive airway pressure in preterm infants.

Nasef Nehad, El-Gouhary Enas, Schurr Patti, Reilly Maureen, Beck Jennifer, Dunn Michael, Ng Eugene

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: High-flow nasal cannulae (HFNC) are increasingly used for respiratory management of preterm infants. However, their ability to provide support compared to nasal continuous positive airway pressure (CPAP) has been questioned. We compared the effect of HFNC versus nasal CPAP on diaphragm electrical activity (EAdi) in preterm infants.

METHODS

Preterm infants ≤1500 g were randomised in a crossover design to receive 2 hours of either Infant Flow(®) CPAP (IF-CPAP) at 5-6 cmH2 O or HFNC with the flow rate adjusted to achieve an equivalent pharyngeal pressure. A feeding catheter with miniaturised sensors was inserted for continuous EAdi measurement.

RESULTS

The study comprised ten infants. Physiologic parameters and oxygen requirements were not different between the two modes. However, seven infants demonstrated a higher EAdi peak and six showed a higher EAdi tonic on HFNC, even though the mean group data showed no difference between HFNC and IF-CPAP. Neural inspiratory time was significantly longer with HFNC than IF-CPAP (0.55 ± 0.11 versus 0.48 ± 0.06 seconds, p = 0.018).

CONCLUSION

In this cohort of preterm infants, the majority exhibited greater diaphragm activation, as assessed by neural breathing patterns, when supported with HFNC than IF-CPAP, suggesting that nasal CPAP may provide more effective respiratory support.

Для цитирования: Nasef Nehad, El-Gouhary Enas, Schurr Patti, Reilly Maureen, Beck Jennifer, Dunn Michael, Ng Eugene. High-flow nasal cannulae are associated with increased diaphragm activation compared with nasal continuous positive airway pressure in preterm infants.. Acta paediatrica (Oslo, Norway : 1992). 2015. DOI: 10.1111/apa.12998.