Physiological dissociation between ventilatory ratio and ventilatory efficiency in patients with ARDS.

Benites Martín H, Suarez-Sipmann Fernando, Santos Arnoldo, Retamal Jaime

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The ventilatory ratio (VR) is frequently used as a surrogate marker of ventilatory efficiency in patients with ARDS. However, its ability to reflect changes in alveolar ventilation (V̇Talv/VT) when respiratory mechanics are modified remains unknown. This study aimed to evaluate the relationship between VR and V̇Talv/VT during sequential changes in respiratory mechanics=, tidal volume (VT), and minute ventilation (V̇E) in patients with ARDS.

METHODS

This was a secondary analysis of a quasi-experimental, repeated-measures study conducted in a single-center adult ICU. Twenty-two patients with ARDS were evaluated across three sequential 60 min controlled periods, during which trunk inclination was adjusted to induce changes in VT. At the end of each period, VR was calculated, and V̇Talv/VT was measured using volumetric capnography. A total of 66 paired measurements were analyzed in this study.

RESULTS

By design, VT increased from Time 1 to Time 2 by + 62 mL and decreased from Time 2 to Time 3 by - 68 mL. These changes in VT were associated with the following: VR was not significantly different between Time 1 and Time 2 [- 0.23 (95% CI: - 0.44 to - 0.02; p = 0.071)] or between Time 2 and Time 3 [+ 0.17 (95% CI: - 0.04 to + 0.38; p = 0.086)]. The alveolar ventilation ratio (V̇Talv/VT) increased significantly from Time 1 to Time 2 by + 0.080 (95% CI: + 0.039 to + 0.121; p < 0.001), and decreased from Time 2 to Time 3 by - 0.060 (95% CI: - 0.101 to - 0.019; p < 0.001). Association between VR and V̇Talv/VT: no significant relationship was found (β =  - 0.056, marginal R2 = 0.052, conditional R2 = 0.205, p = 0.111).

CONCLUSIONS

In this cohort of patients with ARDS, VR did not correlate with V̇Talv/VT following controlled modifications of respiratory mechanics. These findings suggest that VR may not reliably represent ventilatory efficiency under changing ventilatory conditions, and its use as a surrogate variable should be approached with caution.

Для цитирования: Benites Martín H, Suarez-Sipmann Fernando, Santos Arnoldo, Retamal Jaime. Physiological dissociation between ventilatory ratio and ventilatory efficiency in patients with ARDS.. Intensive care medicine experimental. 2026. DOI: 10.1186/s40635-026-00887-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.