Reliability and Validation of the PFIQ-7 and PFDI-20 in the Luganda Language.

Jensen JaNiese Elizabeth, Ngobi Michael Derrick, Kiweewa Flavia Matovu, Fleecs Julia Diane, Vemulapalli Ramya, Steffen Haley Alaine, Wendt Linder Hagstrom, Jackson Jay Brooks, Kenne Kimberly Ann

СтатьяВалидационное исследованиеПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

INTRODUCTION AND HYPOTHESIS: Pelvic floor disorders (PFDs) impact women worldwide and are assessed using instruments such as the Pelvic Floor Distress Inventory (PFDI-20) and Pelvic Floor Impact Questionnaire (PFIQ-7). There are no known valid PFD instruments in Uganda. This study's purpose was to translate and test the reliability and validity of the PFDI-20 and PFIQ-7 in Luganda. It was predicted that these instruments would be reliable and valid to assess the presence and impact of PFD in parous Luganda-speaking women.

METHODS

The translated PFDI-20 and PFIQ-7 were administered to parous Luganda-speaking women and readministered 4-8 months after. The Pelvic Organ Prolapse Quantification (POP-Q) examination determined the presence of pelvic organ prolapse (POP) and a cough-stress test (CST) measured urinary leakage. Analysis was completed using Cronbach's α co-efficient for internal consistency and Spearman's correlation coefficients and Wilcoxon rank sum tests for construct validity.

RESULTS

Of the 159 participants, 93 (58.3%) had stage II POP or higher. The PFDI-20 and PFIQ-7 demonstrated minimal bother and impact on activities of daily living respectively. The Urinary Distress Inventory 6 (UDI-6) scores on the PFDI-20 showed a strong positive association with the presence of urinary incontinence. When PFD was defined by responses to symptom assessment, the translated PFDI-20 and PFIQ-7 could differentiate between individuals with and without PFD.

CONCLUSIONS

The UDI-6 section of the PFDI-20 was found to be valid in Luganda. The PFIQ-7 and the entirety of the PFDI-20 were not found to be reliable or valid, likely because of the low prevalence of PFDs in the study population.

Для цитирования: Jensen JaNiese Elizabeth, Ngobi Michael Derrick, Kiweewa Flavia Matovu, Fleecs Julia Diane, Vemulapalli Ramya, Steffen Haley Alaine, Wendt Linder Hagstrom, Jackson Jay Brooks, Kenne Kimberly Ann. Reliability and Validation of the PFIQ-7 and PFDI-20 in the Luganda Language.. International urogynecology journal. 2024. DOI: 10.1007/s00192-024-05866-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.