MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2025.128523

Медицинская библиотека · Talanta · 2025

Volumetric absorptive microsampling and conductive vial electromembrane extraction for the analysis of pharmaceuticals in whole blood.

Reguli Adam, Dowlatshah Samira, Hansen Frederik André, Štěrbová-Kovaříková Petra, Pedersen-Bjergaard Stig

СтатьяПеревод в очереди

Аннотация

Volumetric absorptive microsampling (VAMS) enables accurate collection of low blood volumes, independent of hematocrit. Electromembrane extraction (EME) is a sustainable sample clean-up technique; however, its wider applicability to extract analytes directly from VAMS tips remains unexplored. This study aimed to evaluate applicability of the first commercially available conductive vial EME device (with 2-nitrophenyl octyl ether as liquid membrane) for isolating 41 basic pharmaceuticals (log P 2-6) from 10 μL of blood on VAMS tips. The following extraction parameters were optimized: donor solution composition and volume, conductive vials size, applied voltage, extraction time and agitation speed. It was found that: 1/large conductive vials (600 μL) and 300 μL of donor solution provide higher process efficiency and reproducibility compared to smaller vials (200 μL) or larger donor solution volumes; 2/methanol in donor solution improve reproducibility and 3/sonication of VAMS tips in donor solution within a conductive vial prior to extraction enhances process efficiency. The EME protocol, followed by UHPLC-MS/MS analysis, was evaluated for process efficiency, linearity (1-1000 ng/mL), precision, and accuracy. Eleven analytes met most of the predefined acceptance criteria: process efficiencies 34.9-65.8 %, linearity (R2) 0.9933-0.9995, accuracy 85.9-111.1 % and precision 1.4-13.3 % RSD. The extraction was not impacted by hematocrit variation. EME demonstrated superior reproducibility and reduced matrix effects when compared to conventional VAMS tips treatment. This study confirms the reliability of a commercial conductive vial EME device for isolating basic pharmaceuticals from whole blood on VAMS tips, highlighting its potential for routine bioanalytical applications.

Для цитирования: Reguli Adam, Dowlatshah Samira, Hansen Frederik André, Štěrbová-Kovaříková Petra, Pedersen-Bjergaard Stig. Volumetric absorptive microsampling and conductive vial electromembrane extraction for the analysis of pharmaceuticals in whole blood.. Talanta. 2025. DOI: 10.1016/j.talanta.2025.128523.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.