MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1078-5884(98)80087-7

Медицинская библиотека · European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 1998

The utility of duplex scanning in infrainguinal vein graft surveillance: results from a randomised controlled study.

Ihlberg L, Luther M, Tierala E, Lepäntalo M

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the utility and efficacy of colour-coded duplex scanning as an adjunct to clinical surveillance of infrainguinal vein bypass surgery.

DESIGN

Prospective controlled randomised trial.

METHODS

The trial included 179 consecutive patients undergoing 185 primary infrainguinal vein graft reconstructions during a 3-year period. Patients alive without amputation and with open graft at 1 month were randomised to a surveillance program based on clinical examination and ankle-brachial pressure index measurement (ABI group) or additional duplex scanning (DD group). All patients were scheduled for surveillance at 1, 3, 6, 9 and 12 months after operation.

RESULTS

Surveillance identified four failing grafts in the ABI group and 11 in the DD group which were revised. The number of occluded grafts was seven in ABI group and 12 in DD group. At 1-year overall cumulative assisted primary patency rates in the ABI group and in the DD group were 74% and 65% respectively (p = 0.21), corresponding secondary patency rates were 84% and 71% (p = 0.04) and limb salvage rates 88% versus 81% (p = 0.23) respectively.

CONCLUSIONS

This study failed to show any beneficial effect of duplex scanning in a surveillance program, which was difficult to accomplish as a part of routine clinical work. However, the main difference in outcome appeared during the first postoperative month before the commencement of the surveillance program.

Для цитирования: Ihlberg L, Luther M, Tierala E, Lepäntalo M. The utility of duplex scanning in infrainguinal vein graft surveillance: results from a randomised controlled study.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 1998. DOI: 10.1016/s1078-5884(98)80087-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.