MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.k.00253

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2012

Return of motor function after segmental nerve loss in a rat model: comparison of autogenous nerve graft, collagen conduit, and processed allograft (AxoGen).

Giusti Guilherme, Willems Wouter F, Kremer Thomas, Friedrich Patricia F, Bishop Allen T, Shin Alexander Y

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

An effective alternative to nerve autograft is needed to minimize morbidity and solve limited-availability issues. We hypothesized that the use of processed allografts and collagen conduits would allow recovery of motor function that is equivalent to that seen after the use of autografts.

METHODS

Sixty-five Lewis rats were divided into three experimental groups. In each group, a unilateral 10-mm sciatic nerve defect was repaired with nerve autograft, allograft treated by AxoGen Laboratories, or a 2.0-mm-inner-diameter collagen conduit. The animals were studied at twelve and sixteen weeks postoperatively. Evaluation included bilateral measurement of the tibialis anterior muscle force and muscle weight, electrophysiology, assessment of ankle contracture, and peroneal nerve histomorphometry. Muscle force was measured with use of our previously described and validated method. Results were expressed as a percentage of the values on the contralateral side. Two-way analysis of variance (ANOVA) corrected by the Ryan-Einot-Gabriel-Welsch multiple range test was used for statistical investigation (α = 0.05).

RESULTS

At twelve weeks, the mean muscle force (and standard deviation), as compared with that on the contralateral (control) side, was 45.2% ± 15.0% in the autograft group, 43.4% ± 18.0% in the allograft group, and 7.0% ± 9.2% in the collagen group. After sixteen weeks, the recovered muscle force was 65.5% ± 14.1% in the autograft group, 36.3% ± 15.7% in the allograft group, and 12.1% ± 16.0% in the collagen group. Autograft was statistically superior to allograft and the collagen conduit at sixteen weeks with regard to all parameters except histomorphometric characteristics (p < 0.05). The collagen-group results were inferior. All autograft-group outcomes improved from twelve to sixteen weeks, with the increase in muscle force being significant.

CONCLUSIONS

The use of autograft resulted in better motor recovery than did the use of allograft or a collagen conduit for a short nerve gap in rats. A longer evaluation time of sixteen weeks after segmental nerve injuries in rats would be beneficial as more substantial muscle recovery was seen at that time.

Для цитирования: Giusti Guilherme, Willems Wouter F, Kremer Thomas, Friedrich Patricia F, Bishop Allen T, Shin Alexander Y. Return of motor function after segmental nerve loss in a rat model: comparison of autogenous nerve graft, collagen conduit, and processed allograft (AxoGen).. The Journal of bone and joint surgery. American volume. 2012. DOI: 10.2106/jbjs.k.00253.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.