MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.70366

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2026

Prevalence and Recovery of Arrhythmia-Induced Cardiomyopathy in Patients With Newly Diagnosed Heart Failure Using a Wearable Defibrillator: A Real-World Cohort Study.

Yogarajah Joerg, Dannebaum Jana, Halim Ahmed, Sedighi Jamschid, Mensch Matthias, Kuniss Malte, Neumann Thomas, Rieth Andreas, Treiber Julia, Sossalla Samuel, Hain Andreas

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Arrhythmia-induced cardiomyopathy (AIC) is a potentially reversible cause of heart failure triggered by different sustained arrhythmias, but data on its real-world prevalence, recognition, and outcomes are limited.

OBJECTIVE

To assess frequency, predictors, and outcomes of AIC in patients with newly diagnosed left ventricular systolic dysfunction (LVSD) and concurrent arrhythmia undergoing early rhythm control with a wearable cardioverter-defibrillator (WCD).

METHODS

Among 780 WCD-treated patients (2017-2023), those with newly diagnosed idiopathic LVSD (LVEF < 35%) and persistent arrhythmia (atrial fibrillation/flutter or > 20% ventricular ectopy) were included. Diagnostic workup comprised echocardiography, coronary angiography, and cardiac MRI. Effective rhythm control was achieved via cardioversion, antiarrhythmic drugs, and/or ablation. Follow-up was up to 6 months. AIC was defined as LVEF improvement > 15% with restored sinus rhythm or suppressed ventricular ectopy.

RESULTS

Of 780 WCD patients, 142 (18.2%) had LVSD with arrhythmia; 74 idiopathic cases were analyzed. At a mean follow-up of 138 days (4.5 months), 54 patients (73%) maintained sinus rhythm or suppressed ventricular ectopy after rhythm control, of whom 32 (59.3%) fulfilled AIC criteria. LVEF improved from 28% to 43% in AIC; 56.3% of AIC patients fully recovered (> 50%). Non-AIC patients had larger LV dimensions, lower heart rates, more mitral regurgitation, and a non-significant trend toward more frequent late gadolinium enhancement (p = 0.073). No parameter reliably predicted AIC; LVEF < 25% predicted lack of full recovery (p = 0.040). No appropriate WCD shocks occurred. ICD indication decreased from 100% to 17% post-therapy in AIC and Non-AIC patients (3.1% vs. 36.4%, p = 0.001).

CONCLUSIONS

AIC related to atrial fibrillation, flutter, or frequent ventricular ectopy is more prevalent and reversible than often recognized. Early rhythm control under WCD protection, supported by comprehensive diagnostics, allows identification of reversible LVSD and may help prevent unnecessary ICD implantation.

Для цитирования: Yogarajah Joerg, Dannebaum Jana, Halim Ahmed, Sedighi Jamschid, Mensch Matthias, Kuniss Malte, Neumann Thomas, Rieth Andreas, Treiber Julia, Sossalla Samuel, Hain Andreas. Prevalence and Recovery of Arrhythmia-Induced Cardiomyopathy in Patients With Newly Diagnosed Heart Failure Using a Wearable Defibrillator: A Real-World Cohort Study.. Journal of cardiovascular electrophysiology. 2026. DOI: 10.1111/jce.70366.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.