MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.70384

Медицинская библиотека · Magnetic resonance in medicine · 2026

Removal of Lipid Artifacts in Amide Proton Transfer Imaging Using Differential Analysis With Fitted Magnetization Transfer and Lipid Signals (DIGITAL).

Dai Zhechuan, Wang Xiaoxia, Yong Xingwang, Zhang Jing, Li Qing, Zhang Jiuquan, Zhang Yi

СтатьяПеревод в очереди

Аннотация

PURPOSE: A differential analysis with fitted magnetization transfer and lipid signals (DIGITAL) method is proposed for eliminating fat artifacts and accurately extracting amide proton transfer (APT) contrast in lipid-rich regions.

THEORY AND

METHODS

The DIGITAL method integrates a two-pool water-magnetization transfer (MT) Bloch-McConnell (BM) model with a six-peak fat Bloch model. Renormalization is employed to correct fat-induced Z-spectrum distortion, and APT# signals are calculated by subtracting the fitted Z-spectrum from the raw Z-spectrum. The proposed DIGITAL method was evaluated using numerical simulations, phantoms, and breast tumor data, with its performance compared against prior multi-pool Lorentzian (MPL) and numerical fitting of extrapolated semisolid magnetization transfer reference signals (NEMR) methods. We also developed a voxel-wise reliability map to assess data and fit quality.

RESULTS

In simulations and experiments, renormalization effectively corrected fat-induced signal scaling and restored the Z-spectrum value at 0 ppm to near 0. The proposed DIGITAL method demonstrated superior uniformity in APT# maps compared to MPL and NEMR. Moreover, DIGITAL was minimally affected by fat, exhibiting high robustness against variations in fat concentrations and a strong linear relationship with amide proton concentrations. In addition, the reliability map functioned as an essential quality assurance tool, enabling the identification of outliers and improving the overall precision of APT analysis.

CONCLUSION

The proposed DIGITAL method can effectively eliminate fat artifacts and extract accurate APT signals without requiring sequence modifications, offering a promising solution to the long-standing challenge of lipid contamination in body APT imaging.

Для цитирования: Dai Zhechuan, Wang Xiaoxia, Yong Xingwang, Zhang Jing, Li Qing, Zhang Jiuquan, Zhang Yi. Removal of Lipid Artifacts in Amide Proton Transfer Imaging Using Differential Analysis With Fitted Magnetization Transfer and Lipid Signals (DIGITAL).. Magnetic resonance in medicine. 2026. DOI: 10.1002/mrm.70384.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.