DOI 10.1080/15428119691014189

Медицинская библиотека · American Industrial Hygiene Association journal · 1996

Prototype instrument employing a microsensor array for the analysis of organic vapors in exhaled breath.

Groves W A, Zellers E T

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

A prototype portable instrument capable of selectively measuring organic vapors in breath at low- and sub-ppm concentrations was tested. The instrument employs an array of four polymer-coated surface-acoustic-wave (SAW) resonators and microprocessor-controlled pumps, valves, and heating elements for preconcentration and thermal desorption of breath samples. Response data are passed to an external personal computer for processing. Sensor responses are based on the reversible changes in the mass and viscoelasticity of the polymeric coatings accompanying vapor sorption. Calibrations were performed for perchloroethylene, trichloroethylene, and methoxyflurane at 100% relative humidity using 15 mg of TenaxTA as the preconcentrator adsorbent. Analyses were then conducted of 250-mL breath samples prepared in Tedlar bags spiked with one of the three solvents within the range of 2 to 18 ppm. Differences between concentrations measured using the prototype instrument and those measured by gas chromatography ranged from -6 to 17% for perchloroethylene. Similar results were obtained for trichloroethylene and methoxyflurane with larger differences occurring at lower concentrations. Estimated limits of detection of 0.7, 0.6, and 4 ppm were achieved for perchloroethylene, trichloroethylene, and methoxyflurane, respectively. These preliminary results demonstrate the feasibility of using SAW sensor technology for field breath analysis.

Для цитирования: Groves W A, Zellers E T. Prototype instrument employing a microsensor array for the analysis of organic vapors in exhaled breath.. American Industrial Hygiene Association journal. 1996. DOI: 10.1080/15428119691014189.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.