DOI 10.1136/bmj.k1310

Медицинская библиотека · BMJ (Clinical research ed.) · 2018

Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis.

Bekiari Eleni, Kitsios Konstantinos, Thabit Hood, Tauschmann Martin, Athanasiadou Eleni, Karagiannis Thomas, Haidich Anna-Bettina, Hovorka Roman, Tsapas Apostolos

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the efficacy and safety of artificial pancreas treatment in non-pregnant outpatients with type 1 diabetes.

DESIGN

Systematic review and meta-analysis of randomised controlled trials.

DATA SOURCES: Medline, Embase, Cochrane Library, and grey literature up to 2 February 2018.

ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Randomised controlled trials in non-pregnant outpatients with type 1 diabetes that compared the use of any artificial pancreas system with any type of insulin based treatment. Primary outcome was proportion (%) of time that sensor glucose level was within the near normoglycaemic range (3.9-10 mmol/L). Secondary outcomes included proportion (%) of time that sensor glucose level was above 10 mmol/L or below 3.9 mmol/L, low blood glucose index overnight, mean sensor glucose level, total daily insulin needs, and glycated haemoglobin. The Cochrane Collaboration risk of bias tool was used to assess study quality.

RESULTS

40 studies (1027 participants with data for 44 comparisons) were included in the meta-analysis. 35 comparisons assessed a single hormone artificial pancreas system, whereas nine comparisons assessed a dual hormone system. Only nine studies were at low risk of bias. Proportion of time in the near normoglycaemic range (3.9-10.0 mmol/L) was significantly higher with artificial pancreas use, both overnight (weighted mean difference 15.15%, 95% confidence interval 12.21% to 18.09%) and over a 24 hour period (9.62%, 7.54% to 11.7%). Artificial pancreas systems had a favourable effect on the proportion of time with sensor glucose level above 10 mmol/L (-8.52%, -11.14% to -5.9%) or below 3.9 mmol/L (-1.49%, -1.86% to -1.11%) over 24 hours, compared with control treatment. Robustness of findings for the primary outcome was verified in sensitivity analyses, by including only trials at low risk of bias (11.64%, 9.1% to 14.18%) or trials under unsupervised, normal living conditions (10.42%, 8.63% to 12.2%). Results were consistent in a subgroup analysis both for single hormone and dual hormone artificial pancreas systems.

CONCLUSIONS

Artificial pancreas systems are an efficacious and safe approach for treating outpatients with type 1 diabetes. The main limitations of current research evidence on artificial pancreas systems are related to inconsistency in outcome reporting, small sample size, and short follow-up duration of individual trials.

Для цитирования: Bekiari Eleni, Kitsios Konstantinos, Thabit Hood, Tauschmann Martin, Athanasiadou Eleni, Karagiannis Thomas, Haidich Anna-Bettina, Hovorka Roman, Tsapas Apostolos. Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis.. BMJ (Clinical research ed.). 2018. DOI: 10.1136/bmj.k1310.

Предметные рубрики MeSH