MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2022-069876

Медицинская библиотека · BMJ open · 2023

Using pooled urogenital, anorectal and oropharyngeal specimens to detect Chlamydia trachomatis and Neisseria gonorrhoeae among men who have sex with men in China: a multisite diagnostic accuracy study.

Jiang Ting-Ting, Cao Ning-Xiao, Shi Mei-Qin, Jia Tian-Jian, Zhou Qian, Liu Jing-Wei, Zhang Jin, Zhang Yan, Yin Yue-Ping, Chen Xiang-Sheng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Screening for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) at both urogenital and extragenital sites has been recommended in many countries. Testing of the infections using pooled specimens from urogenital and extragenital sites offer the opportunity to shorten the testing time and reduce the testing cost. Ex-ante pooling is placing the original single-site specimens in a tube with transport media, while ex-post pooling is making a pool of the transport media from both anorectal and oropharyngeal specimens and the urine. This study aimed to conduct a multisite performance evaluation of two pool-specimen approaches (ex-ante and ex-post) in detection of CT and NG using the Cobas 4800 platform among men who have sex with men (MSM) in China.

DESIGN

Diagnostic accuracy study.

SETTING, PARTICIPANTS AND OUTCOME MEASURES: Participants were recruited from MSM communities at six cities in China. Two oropharyngeal and anorectal swabs collected by clinical staff and 20 mL first-void urine collected by the participant himself were used for evaluating sensitivity and specificity.

RESULTS

A total of 1311 specimens were collected from 437 participants in six cities. The sensitivities of ex-ante pooling approach as compared with single-specimen approach (reference standard) were 98.7% (95% CI, 92.7% to 100.0%) for detection of CT and 89.7% (95% CI, 75.8% to 97.1%) for NG, and the specificities were 99.5% (95% CI, 98.0% to 99.9%) and 98.7% (95% CI, 97.1% to 99.6%), respectively. The sensitivities of ex-post pooling approach were 98.7% (95% CI, 92.7% to 100.0%) for CT and 100.0% (95% CI, 91.0% to 100.0%) for NG, and the specificities were 100.0% (95% CI, 99.0% to 100.0%) and 100.0% (95% CI, 99.1% to 100.0%), respectively.

CONCLUSIONS

The ex-ante and ex-post pooling approaches show good sensitivity and specificity in detecting urogenital and extragenital CT and/or NG, indicating that these approaches can be used in epidemiological surveillance and clinical management of CT and NG infections, particularly among MSM population.

Для цитирования: Jiang Ting-Ting, Cao Ning-Xiao, Shi Mei-Qin, Jia Tian-Jian, Zhou Qian, Liu Jing-Wei, Zhang Jin, Zhang Yan, Yin Yue-Ping, Chen Xiang-Sheng. Using pooled urogenital, anorectal and oropharyngeal specimens to detect Chlamydia trachomatis and Neisseria gonorrhoeae among men who have sex with men in China: a multisite diagnostic accuracy study.. BMJ open. 2023. DOI: 10.1136/bmjopen-2022-069876.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.