MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0020-1383(93)90031-z

Медицинская библиотека · Injury · 1993

External fixator pin placement in the forearm: how safe is it? An anatomical study.

Chissell H R, Patel A D

СтатьяПеревод в очереди

Аннотация

An anatomical study was undertaken using cadaveric forearms to identify the best technique and angle of pin placement for external fixator pins. We have found that inserting pins through stab incisions risks transfixion of the underlying structures and leads to an increased morbidity. We conclude that inserting pins under direct vision is much safer and that the optimum angle of pin insertion is in the coronal plane, parallel to the plane of the metacarpals.

Для цитирования: Chissell H R, Patel A D. External fixator pin placement in the forearm: how safe is it? An anatomical study.. Injury. 1993. DOI: 10.1016/0020-1383(93)90031-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.