MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1121/10.0044505

Медицинская библиотека · The Journal of the Acoustical Society of America · 2026

Phase-coherence volumetric ultrasonic imaging of full matrix capture data using row-column-addressed array.

Li Xuan, Liu Lishuai, Wang Shijun, Zhang Yuncheng, Zhang Rui, Xiang Yanxun, Xuan Fu-Zhen

СтатьяПеревод в очереди

Аннотация

Row-column-addressed (RCA) arrays enable three-dimensional (3D) volumetric ultrasonic imaging with significantly reduced channel count and system complexity compared with fully addressed planar arrays. However, their imaging performance is limited by steering-angle-dependent acoustic fields and receive sensitivity, which can lead to degraded off-axis resolution, elevated sidelobes, and ghost artifacts. To address these challenges, this study proposes a systematic phase-coherence-based imaging framework for enhancing 3D volumetric imaging quality using full matrix capture data acquired with RCA arrays. A suite of 3D imaging algorithms is developed based on different statistical phase-coherence measures, enabling effective suppression of incoherent contributions in the beamformed signals. Experimental results demonstrate that phase-coherence weighting substantially improves contrast ratio and reduces imaging artifacts compared with conventional delay-and-sum based approaches. Among the evaluated methods, the sign coherence factor achieves a favorable balance between computational efficiency and imaging performance while effectively mitigating near-field effects. Overall, these results demonstrate the feasibility of achieving high-quality 3D volumetric ultrasonic imaging with RCA arrays and highlight the potential of phase-coherence-based strategies to provide robust and interpretable volumetric reconstructions for a broad range of ultrasonic imaging applications.

Для цитирования: Li Xuan, Liu Lishuai, Wang Shijun, Zhang Yuncheng, Zhang Rui, Xiang Yanxun, Xuan Fu-Zhen. Phase-coherence volumetric ultrasonic imaging of full matrix capture data using row-column-addressed array.. The Journal of the Acoustical Society of America. 2026. DOI: 10.1121/10.0044505.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.