MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0018720808329843

Медицинская библиотека · Human factors · 2009

Providing training enhances the biomechanical improvements of an alternative computer mouse design.

Houwink Annemieke, Oude Hengel Karen M, Odell Dan, Dennerlein Jack T

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study is to determine if an alternative mouse promotes more neutral postures and decreases forearm muscle activity and if training enhances these biomechanical benefits.

BACKGROUND

Computer mouse use is a risk factor for developing musculoskeletal disorders; alternative mouse designs can help lower these risks. Ergonomic training combined with alternative input devices could be even more effective than alternative designs alone.

METHODS

Thirty healthy adults (15 males, 15 females) performed a set of computer mouse tasks with a standard mouse and an alternative mouse while an electromagnetic motion analysis system measured their wrist and forearm postures and surface electromyography measured the muscle activity of three wrist extensor muscles. Fifteen participants received no training on how to hold the alternative mouse, whereas the remaining 15 participants received verbal instructions before and during use of the alternative mouse.

RESULTS

The alternative mouse was found to promote a more neutral forearm posture compared with the standard mouse (up to 11.5 degrees lower forearm pronation); however, pronation was further reduced when instructions on how to hold the mouse were provided. Wrist extensor muscle activity was reduced for the alternative mouse (up to 1.8% of maximum voluntary contraction lower) compared with the standard mouse, but only after participants received instructions.

CONCLUSION

The alternative mouse design decreased biomechanical exposures; however, instructions enhanced this potential ergonomic benefit of the design.

APPLICATION: User knowledge and training are important factors when effectively implementing an alternative ergonomic device.

Для цитирования: Houwink Annemieke, Oude Hengel Karen M, Odell Dan, Dennerlein Jack T. Providing training enhances the biomechanical improvements of an alternative computer mouse design.. Human factors. 2009. DOI: 10.1177/0018720808329843.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.