MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jos.jos_82_23

Медицинская библиотека · Journal of orthodontic science · 2024

Displacement and stress distribution pattern during complete mandibular arch distalization using buccal shelf bone screws - A three-dimensional finite element study.

Priya Parul, Jain Abhay Kumar, Prasad Raghu Ranjan, Singh Shresthaa, Kumar Abhishek, Kumari Priyanka

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To evaluate and compare the distribution of stress and displacement of teeth during mandibular arch distalization using buccal shelf screws.

MATERIALS AND

METHODS

Three three-dimensional finite element models of mandibular arch were constructed with third molars extracted. Models 1, 2, and 3 were constructed on the basis of the lever arm heights of 0 mm, 3 mm, and 6 mm, respectively, between the lateral incisor and canine. A buccal shelf screw was placed at the area in the second molar region with the initial point of insertion being inter-dental between the first and second molars and 2 mm below the mucogingival junction. MBT pre-adjusted brackets (slot size 0.022 × 0.028") were placed over the clinical crown's center with a 0.019 × 0.025" stainless-steel archwire on three models. A retraction force of 300 g was applied with buccal shelf screws and a lever arm bilaterally using nickel-titanium closed coil springs. The displacement of each tooth was calculated on X, Y, and Z axes, and the von Mises stress distribution was visualized using color-coded scales using ANSYS 12.1 software.

RESULT: The maximum von Mises stress in the cortical and cancellous bones was observed in model 1. The maximum von Mises stress in the buccal shelf screw and the cortical bone decreased as the height of the lever arm increased. Applying orthodontic forces at the level of 6 mm lever arm height resulted in greater biomechanical bodily movement in distalization of the mandibular molars compared to when the orthodontic forces were applied at the level of 0 mm lever arm height.

CONCLUSION

Displacement of the entire arch may be dictated by a direct relationship between the center of resistance of the whole arch and the line of action generated between the buccal shelf screw and force application points at the archwire, which makes the total arch movement highly predictable.

Для цитирования: Priya Parul, Jain Abhay Kumar, Prasad Raghu Ranjan, Singh Shresthaa, Kumar Abhishek, Kumari Priyanka. Displacement and stress distribution pattern during complete mandibular arch distalization using buccal shelf bone screws - A three-dimensional finite element study.. Journal of orthodontic science. 2024. DOI: 10.4103/jos.jos_82_23.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.