Inspiratory effort increases blood volume in the thoracic cavity and decreases end-expiratory lung impedance: a preliminary prospective study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Takahashi Kazuhiro, Koyama Ayaka, Irimada Daisuke, Kanaya Akihiro, Konno Daisuke, Kaiho Yu, Takei Yusuke, Saito Kazutomo, Ejima Yutaka, Yamauchi Masanori
Аннотация
PURPOSE: Passive leg raising (PLR) increases intrathoracic blood volume by redistributing blood from the lower to the upper body area. While inspiratory effort is hypothesized to have a similar effect due to pressure differences between the intrathoracic and extrathoracic cavities, direct evidence is scarce. Therefore, this study evaluated whether excessive inspiratory effort increases intrathoracic blood volume using end-expiratory lung impedance (EELI).
METHODS: Volunteers, fitted with electrical impedance tomography (EIT) belts, underwent a spontaneous breathing procedure in the supine position (control step). They breathed through a specialized face mask with separated inspiration and expiration routes (one-way valves) and their EELI was continuously recorded. First, PLR was performed. Subsequently, resistors (3-mm and 2-mm) were sequentially added to the mask's inspiration route, requiring volunteers to increase inspiratory effort. A reference EELI was established during spontaneous breathing, and changes in EELI (ΔEELI) were calculated for each step (control, PLR, 3-mm, and 2-mm). ΔEELI values were compared using the Friedman test and Wilcoxon signed-rank test with Holm's P value adjustment.
RESULTS: Across 11 participants, the mean ΔEELI decreased by 13, 18, and 19 units for PLR, 3-mm, and 2-mm resistors, respectively. The Friedman test and Wilcoxon signed-rank test revealed significant differences between the control and each aforementioned intervention.
CONCLUSION: PLR and increased inspiratory effort augment thoracic blood volume, thereby reducing EELI.
REGISTRATION: UMIN000054238. April/23/2024.
METHODS: Volunteers, fitted with electrical impedance tomography (EIT) belts, underwent a spontaneous breathing procedure in the supine position (control step). They breathed through a specialized face mask with separated inspiration and expiration routes (one-way valves) and their EELI was continuously recorded. First, PLR was performed. Subsequently, resistors (3-mm and 2-mm) were sequentially added to the mask's inspiration route, requiring volunteers to increase inspiratory effort. A reference EELI was established during spontaneous breathing, and changes in EELI (ΔEELI) were calculated for each step (control, PLR, 3-mm, and 2-mm). ΔEELI values were compared using the Friedman test and Wilcoxon signed-rank test with Holm's P value adjustment.
RESULTS: Across 11 participants, the mean ΔEELI decreased by 13, 18, and 19 units for PLR, 3-mm, and 2-mm resistors, respectively. The Friedman test and Wilcoxon signed-rank test revealed significant differences between the control and each aforementioned intervention.
CONCLUSION: PLR and increased inspiratory effort augment thoracic blood volume, thereby reducing EELI.
REGISTRATION: UMIN000054238. April/23/2024.