Clinical spine surgery · 2017
Kirschner Wire and Bone Cement is a Viable Alternative to Reconstruction of Large Iliac Bone Defects After Strut Bone Graft Harvesting.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yu Shang-Won, Wu Chin-Hsien, Yeh James Jih-Hsi, Yen Cheng-Yo, Ma Ching-Hou, Tu Yuan-Kun
Аннотация
STUDY DESIGN: A retrospective study.
OBJECTIVE: To assess the safety and efficacy of iliac crest defect reconstruction using Kirschner wire (K-wire)/polymethylmethacrylate (PMMA) versus traditional autologous rib graft reconstruction.
SUMMARY OF BACKGROUND DATA: The iliac crest has been the preferred donor site for strut bone graft for various spinal fusion surgeries.
METHODS: Seventy-three patients (44 males and 29 females; average age: 57.2 y) were divided into 2 groups: the rib group (35 patients) and the K-wire/PMMA group (38 patients). All operations involved anterior spinal interbody fusion. Patients were followed-up, on average, for 34.2 months using plain radiographs and both pain and cosmesis visual analog scales (VAS) to assess the clinical results after surgery.
RESULTS: Almost all patients had pain VAS scores of ≤1 and grade 1 cosmesis VAS scores with no significant difference between the 2 groups in terms of either pain or cosmesis (P=1.00 and 0.505, respectively). In addition, few complications were noted in both groups. Radiographic complications in the rib group and the K-wire group numbered 4 (11%) and 2 (5%), respectively; however, did not significantly differ between the 2 groups (P=0.418). One case required intraoperative revision of the length of the K-wire and 1 case needed reoperation for iliac ring fracture and K-wire migration. An additional case required revision due to a bad fall.
CONCLUSIONS: K-wire and bone cement reconstruction is an effective and safe alternative method for large iliac bone defect repair when autologous rib graft is not available.
OBJECTIVE: To assess the safety and efficacy of iliac crest defect reconstruction using Kirschner wire (K-wire)/polymethylmethacrylate (PMMA) versus traditional autologous rib graft reconstruction.
SUMMARY OF BACKGROUND DATA: The iliac crest has been the preferred donor site for strut bone graft for various spinal fusion surgeries.
METHODS: Seventy-three patients (44 males and 29 females; average age: 57.2 y) were divided into 2 groups: the rib group (35 patients) and the K-wire/PMMA group (38 patients). All operations involved anterior spinal interbody fusion. Patients were followed-up, on average, for 34.2 months using plain radiographs and both pain and cosmesis visual analog scales (VAS) to assess the clinical results after surgery.
RESULTS: Almost all patients had pain VAS scores of ≤1 and grade 1 cosmesis VAS scores with no significant difference between the 2 groups in terms of either pain or cosmesis (P=1.00 and 0.505, respectively). In addition, few complications were noted in both groups. Radiographic complications in the rib group and the K-wire group numbered 4 (11%) and 2 (5%), respectively; however, did not significantly differ between the 2 groups (P=0.418). One case required intraoperative revision of the length of the K-wire and 1 case needed reoperation for iliac ring fracture and K-wire migration. An additional case required revision due to a bad fall.
CONCLUSIONS: K-wire and bone cement reconstruction is an effective and safe alternative method for large iliac bone defect repair when autologous rib graft is not available.