MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-023-10097-1

Медицинская библиотека · European radiology · 2023

Transcatheter arterial chemoembolization using CalliSpheres beads loaded with arsenic trioxide for unresectable large or huge hepatocellular carcinoma: a prospective study.

Duan Xuhua, Li Hao, Chen Pengfei, Sun Tao, Kuang Donglin, Lu Huibin, Qiao Bingbing, Fan Zhengjun, Ren Zhuangjian, Han Xinwei

Рандомизированное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the safety and efficacy of transcatheter arterial chemoembolization with CalliSpheres® beads loaded with arsenic trioxide (CBATO-TACE) in the first-line treatment of patients with large (5 cm ≤ maximum diameter < 10 cm) or huge (maximum diameter ≥ 10 cm) hepatocellular carcinoma (HCC).

METHODS

Patients were randomly allocated to the CBATO-TACE group and the conventional transcatheter arterial chemoembolization (cTACE) group. The primary endpoint was progression-free survival (PFS). The secondary endpoint was overall survival (OS), treatment response, and treatment-related adverse events (TRAEs). The extrahepatic collateral arteries, liver function, and liver fibrosis after the first TACE were also evaluated.

RESULTS

From September 2018 to September 2020, a total of 207 patients who underwent TACE were consecutively enrolled in this study. The median PFS was 9.5 months (range: 8.0 - 11.0) in the CBATO group, which was significantly longer than that in the cTACE group (6.0 months, range: 4.0-6.0) (p < 0.0001). Patients in the CBATO group had a median OS of 22 months (range: 20.0 - 27.0) compared with 16 months (range: 15.0 - 20.0) in the cTACE group (p = 0.0084). The most common TRAEs were fever (p = 0.043), and nausea and vomiting (p = 0.002), which were more observed in the cTACE group. In addition, the progressive disease time, pulmonary metastasis rate (p = 0.01), the mean number of extrahepatic collateral arteries (p = 0.01), and average number of TACE sessions (p = 0.025) were significantly decreased in the CBATO group.

CONCLUSIONS

CBATO-TACE achieved better therapeutic outcomes and similar safety profile compared to cTACE in large or huge HCC patients. Furthermore, CBATO-TACE was able to reduce extrahepatic collateral arteries production and extrahepatic lung metastasis.

CLINICAL RELEVANCE STATEMENT: Our study showed that CalliSpheres® beads loaded with arsenic trioxide (CBATO-TACE) were effective and safe for the treatment of large and giant HCC. In addition, CBATO-TACE can reduce lateral hepatic branch artery formation and extrahepatic pulmonary metastasis, which provides a new treatment approach for unresectable HCC.

KEY POINTS: • We compare long-term efficacy and safety of transcatheter arterial chemoembolization with CalliSpheres® beads loaded with arsenic trioxide (CBATO-TACE) and conventional transcatheter arterial chemoembolization (cTACE) in patients with large (5 cm ≤ maximum diameter < 10 cm) or huge HCC (maximum diameter ≥ 10 cm). • Compared with cTACE, CBATO-TACE significantly improved therapeutic outcomes, overall survival, and progression-free survival in patients with large or huge HCC. The safety assessment suggested that CBATO-TACE is a safe treatment that improves the quality of life and has good treatment adherence.

Для цитирования: Duan Xuhua, Li Hao, Chen Pengfei, Sun Tao, Kuang Donglin, Lu Huibin, Qiao Bingbing, Fan Zhengjun, Ren Zhuangjian, Han Xinwei. Transcatheter arterial chemoembolization using CalliSpheres beads loaded with arsenic trioxide for unresectable large or huge hepatocellular carcinoma: a prospective study.. European radiology. 2023. DOI: 10.1007/s00330-023-10097-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.