MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-018-6140-1

Медицинская библиотека · Surgical endoscopy · 2018

A blunt dissection technique using the LigaSure vessel-sealing device improves perioperative outcomes and postoperative splenic-vessel patency after laparoscopic spleen- and splenic-vessel-preserving distal pancreatectomy.

Kim Sungho, Yoon Yoo-Seok, Han Ho-Seong, Cho Jai Young, Choi YoungRok, Hyun In Gun, Kim Kil Hwan

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

We have recently performed a blunt dissection technique using LigaSure technology for laparoscopic spleen- and splenic-vessel-preserving distal pancreatectomy to reduce the risk of bleeding during the dissection of the splenic vessels. The aim of this study was to compare the utility of the blunt dissection technique and a conventional dissection technique during laparoscopic spleen- and splenic-vessel-preserving distal pancreatectomy.

METHODS

Fifty-five patients who underwent laparoscopic spleen- and splenic-vessel-preserving distal pancreatectomy performed by a single surgeon between March 2003 and December 2015 were enrolled in this retrospective single-center study. The patients were divided into the LigaSure group (n = 23) and non-LigaSure group (n = 26). Perioperative clinical outcomes and the postoperative patency of the preserved splenic vessels in the two groups were compared.

RESULTS

The patient and tumor characteristics did not differ significantly between the two groups. The incidence of postoperative complications was similar in the two groups. However, the mean operative time (145 vs. 231.1 min, P = 0.001), intraoperative blood loss (95.6 vs. 360 ml, P = 0.001), and postoperative hospital stay (6.4 vs. 9.8 days, P = 0.001) were significantly lower in the LigaSure group than in the non-LigaSure group, respectively. The splenic artery patency rate was similar in both groups, but the splenic vein patency was significantly better in the LigaSure group than in the non-LigaSure group (total occlusion rate: 4.5 vs. 30.8%, respectively, P = 0.017).

CONCLUSION

The results of this study suggest that the blunt dissection technique using a LigaSure reduces the operating time and intraoperative blood loss during laparoscopic spleen- and splenic-vessel-preserving distal pancreatectomy and increases the patency of the preserved splenic vessels.

Для цитирования: Kim Sungho, Yoon Yoo-Seok, Han Ho-Seong, Cho Jai Young, Choi YoungRok, Hyun In Gun, Kim Kil Hwan. A blunt dissection technique using the LigaSure vessel-sealing device improves perioperative outcomes and postoperative splenic-vessel patency after laparoscopic spleen- and splenic-vessel-preserving distal pancreatectomy.. Surgical endoscopy. 2018. DOI: 10.1007/s00464-018-6140-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.