Chest · 2007
Tiotropium and simplified detection of dynamic hyperinflation.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gelb Arthur F, Taylor Colleen Flynn, McClean Patricia A, Shinar Chris M, Rodrigues Marcelo T, Gutierrez Carlos A, Chapman Kenneth R, Zamel Noe
Аннотация
STUDY OBJECTIVE: To detect dynamic hyperinflation (DH) by evaluating reduction in inspiratory capacity (IC) during metronome-paced hyperventilation (MPH) in patients with moderate-to-severe COPD, studied before and after treatment with tiotropium.
METHODS: IC and FEV(1) were measured before and immediately after MPH at two times resting the respiratory rate for 20 s in 60 COPD patients (28 men; mean age, 66 +/- 10 years [+/- SD]) before and after 30 days of treatment with tiotropium bromide, 18 mug. Patients were encouraged to maintain a constant tidal volume during MPH.
RESULTS: At baseline, mean FEV(1) was 1.5 +/- 0.1 L (+/- SE) [57 +/- 1.6% of predicted], mean FVC was 2.6 +/- 0.1L (77 +/- 1.8% of predicted), and mean FEV(1)/FVC was 56 +/- 1%. After 180 mug of aerosolized albuterol sulfate, mean FEV(1) was 1.7 +/- 0.1 L (63 +/- 1.5% of predicted) [p < 0.001] and mean FEV(1)/FVC was 58 +/- 1%. Compared to baseline, after 30 days and 1.5 h after tiotropium there was an increase in IC of 0.18 +/- 0.04L (p < 0.0001); FEV(1) of 0.13 +/- 0.03 L (5.6 +/- 0.8% of predicted; p = 0.0002); FVC of 0.22 +/- 0.05 L (6.5 +/- 1.3% of predicted; p < 0.001); and decrease in end-expiratory lung volume (EELV)/total lung capacity (TLC) of - 3.1 +/- 0.6% (p = 0.0001); a decrease in end-inspiratory lung volume (EILV)/TLC of - 2.9 +/- 1.3% (p = 0.03); and no change in TLC (- 0.06 +/- 0.05 L). Results following MPH-induced DH at baseline and after 30 days of tiotropium were similar, with decreases in IC (- 0.35 +/- 0.03 L; p < 0.001); FEV(1) (- 0.05 +/- 0.04 L; p = 0.2); and FVC (- 0.22 +/- 0.03 L; p < 0.0001); no change in TLC; and increases in EELV/TLC (11.8 +/- 1.0% of predicted; p < 0.0001) and EILV/TLC (4.0 +/- 1.3% of predicted, p < 0.003).
CONCLUSION: In patients with moderate-to-severe COPD, tiotropium did not reduce MPH-induced DH and reduction in IC, compared to baseline. However, because tiotropium induced bronchodilation and increased baseline IC, lower operational lung volumes may blunt the effect of MPH-induced DH. The noninvasive simplicity of MPH-induced DH provides a clinically useful screening surrogate to monitor changes in IC following treatment with tiotropium.
METHODS: IC and FEV(1) were measured before and immediately after MPH at two times resting the respiratory rate for 20 s in 60 COPD patients (28 men; mean age, 66 +/- 10 years [+/- SD]) before and after 30 days of treatment with tiotropium bromide, 18 mug. Patients were encouraged to maintain a constant tidal volume during MPH.
RESULTS: At baseline, mean FEV(1) was 1.5 +/- 0.1 L (+/- SE) [57 +/- 1.6% of predicted], mean FVC was 2.6 +/- 0.1L (77 +/- 1.8% of predicted), and mean FEV(1)/FVC was 56 +/- 1%. After 180 mug of aerosolized albuterol sulfate, mean FEV(1) was 1.7 +/- 0.1 L (63 +/- 1.5% of predicted) [p < 0.001] and mean FEV(1)/FVC was 58 +/- 1%. Compared to baseline, after 30 days and 1.5 h after tiotropium there was an increase in IC of 0.18 +/- 0.04L (p < 0.0001); FEV(1) of 0.13 +/- 0.03 L (5.6 +/- 0.8% of predicted; p = 0.0002); FVC of 0.22 +/- 0.05 L (6.5 +/- 1.3% of predicted; p < 0.001); and decrease in end-expiratory lung volume (EELV)/total lung capacity (TLC) of - 3.1 +/- 0.6% (p = 0.0001); a decrease in end-inspiratory lung volume (EILV)/TLC of - 2.9 +/- 1.3% (p = 0.03); and no change in TLC (- 0.06 +/- 0.05 L). Results following MPH-induced DH at baseline and after 30 days of tiotropium were similar, with decreases in IC (- 0.35 +/- 0.03 L; p < 0.001); FEV(1) (- 0.05 +/- 0.04 L; p = 0.2); and FVC (- 0.22 +/- 0.03 L; p < 0.0001); no change in TLC; and increases in EELV/TLC (11.8 +/- 1.0% of predicted; p < 0.0001) and EILV/TLC (4.0 +/- 1.3% of predicted, p < 0.003).
CONCLUSION: In patients with moderate-to-severe COPD, tiotropium did not reduce MPH-induced DH and reduction in IC, compared to baseline. However, because tiotropium induced bronchodilation and increased baseline IC, lower operational lung volumes may blunt the effect of MPH-induced DH. The noninvasive simplicity of MPH-induced DH provides a clinically useful screening surrogate to monitor changes in IC following treatment with tiotropium.
Предметные рубрики MeSH
AgedAlbuterolBronchodilator AgentsFemaleForced Expiratory VolumeFunctional Residual CapacityHumansHyperventilationInspiratory CapacityMaleMiddle AgedPlethysmography, Whole BodyPulmonary Disease, Chronic ObstructiveResidual VolumeScopolamine DerivativesSmokingSpirometryTiotropium BromideTotal Lung CapacityTreatment OutcomeVital Capacity