MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00192-009-0953-3

Медицинская библиотека · International urogynecology journal and pelvic floor dysfunction · 2009

Synthetic graft use in vaginal prolapse surgery: objective and subjective outcomes.

Wetta Luisa A, Gerten Kimberly A, Wheeler Thomas L, Holley Robert L, Varner R Edward, Richter Holly E

СтатьяПеревод в очереди

Аннотация

INTRODUCTION AND HYPOTHESIS: This study reports 1-year outcomes in women who underwent transvaginal pelvic organ prolapse (POP) surgery with Prolift transvaginal mesh.

METHODS

Pre- and postoperative objective vaginal Pelvic Organ Prolapse Quantification (POP-Q) and subjective symptom and impact assessments (Pelvic Floor Distress Inventory (PFDI)-20 and Pelvic Floor Impact Questionnaire (PFIQ)-7, respectively) were performed. Postoperative vaginal tenderness, stricture, and patient satisfaction were also obtained. Paired t tests were utilized for analysis.

RESULTS

Mean age was 61.8 +/- 9.8 years; mean follow-up interval was 425.0 +/- 80.0 days (range, 237-717). POP-Q measurements of Ba, Bp, and C were significantly improved (all p values <or= 0.001). PFDI and PFIQ subscale scores significantly improved (all p values <or= 0.004). Thirty-five of 48 (73%) were completely satisfied, and two (4%) were not satisfied. Complications (n (percent)) included graft exposure (1 (2%)), dyspareunia (2 (4%)), and granulation tissue (3 (6%)).

CONCLUSIONS

Women undergoing transvaginal repair of POP with the Prolift mesh system showed significant improvement in 1-year anatomic and subjective measures.

Для цитирования: Wetta Luisa A, Gerten Kimberly A, Wheeler Thomas L, Holley Robert L, Varner R Edward, Richter Holly E. Synthetic graft use in vaginal prolapse surgery: objective and subjective outcomes.. International urogynecology journal and pelvic floor dysfunction. 2009. DOI: 10.1007/s00192-009-0953-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.