MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Indian pediatrics · 2006

Dose end-tidal carbon dioxide measurement correlate with arterial carbon dioxide in extremely low birth weight infants in the first week of life?

Amuchou Singh Soraisham, Singhal Nalini

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To study the correlation and agreement between end-tidal carbon dioxide (EtCO2) and arterial carbon dioxide (PaCO(2)) in ventilated extremely low birth weight (ELBW) infants in the first week of life.

METHODS

Retrospective chart review of all ELBW (<1,000 g) infants admitted to a level III NICU from January 2003 to December 2003. Data collected included demographic details and simultaneous EtCO(2) (mainstream capnography) and arterial blood gas values (pH, PaCO(2), PaO(2)).

OUTCOME: The correlation coefficient, degree of bias with 95% confidence interval between the EtCO(2) and PaCO(2).

RESULTS

There were 754 end-tidal and arterial CO(2) pairs from 31 ELBW infants (21 male and 10 female). The overall EtCO(2) values were significantly lower than PaCO(2) value. In only 89/754(11.8%) pairs, the EtCO(2) was higher than the PaCO(2). The overall bias was 5.6 +/- 6.9 mmHg (95% C.I. 5.11-6.09). The intraclass correlation coefficient was 0.81. Using EtCO2 ranges of 30 to 50 mmHg, the capnographic method was able to identify 84% of instances where PaCO(2) was between 35 (<35 = hypocarbia) and 55 mmHg (>55= hypercapnia).

CONCLUSIONS

There is good correlation and agreement between end-tidal CO(2) and arterial CO(2) in ELBW infants in the EtCO(2) range 30-50 mmHg. End-tidal CO(2) monitoring can be helpful in trending or for screening abnormal PaCO(2) values in ELBW infants in first week of life.

Для цитирования: Amuchou Singh Soraisham, Singhal Nalini. Dose end-tidal carbon dioxide measurement correlate with arterial carbon dioxide in extremely low birth weight infants in the first week of life?. Indian pediatrics. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.