MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1067/mpd.2001.110978

Медицинская библиотека · The Journal of pediatrics · 2001

Skin-to-skin (kangaroo) care, respiratory control, and thermoregulation.

Bohnhorst B, Heyne T, Peter C S, Poets C F

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: To demonstrate that skin-to-skin care (SSC) has no detrimental effects on the frequency of episodes of bradycardia and/or hypoxemia.

METHODS

Twenty-two spontaneously breathing preterm infants (median gestational age at birth, 29 weeks [range, 24-31 weeks]; age at study, 26 days [range, 7-72 days]; weight at study, 1310 g [range, 725-1890 g]) had three 2-hour recordings of breathing movements, nasal airflow, heart rate, and oxygen saturation as measured by pulse oximetry (SpO(2)) before, during, and after SSC. Rectal temperature was obtained every 2 hours. Recordings were analyzed for baseline heart and respiratory rates, bradycardia (heart rate < two thirds of baseline), and hypoxemia (SpO(2) < or =80%), as well as for breathing pattern (regular vs non-regular).

RESULTS

Baseline heart rate and respiratory rate increased during SSC (P <.01), as did the combined frequency of bradycardia and hypoxemia (from 1.5/h [0-8] before to 2.8/h [0-15] during SSC; P<.05). Rectal temperature increased from 36.9 degrees C (36.2 degrees -37.4 degrees C) to 37.3 degrees C (36.6 degrees -38.6 degrees C; P <.01). The proportion of regular breathing pattern decreased from 14% (2%-28%) to 7% (3%-26%) with SSC (P<.01).

CONCLUSION

SSC was associated with a significant increase in the combined frequency of bradycardia and hypoxemia and with less regular breathing. These changes were unexpected and may have been related to heat stress. Body temperature, heart rate, and oxygenation should be monitored during SSC.

Для цитирования: Bohnhorst B, Heyne T, Peter C S, Poets C F. Skin-to-skin (kangaroo) care, respiratory control, and thermoregulation.. The Journal of pediatrics. 2001. DOI: 10.1067/mpd.2001.110978.