Development of an E-Nose System for the Early Diagnosis of Sepsis During Mechanical Ventilation: A Porcine Feasibility Study.

Robbiani Stefano, Te Nijenhuis Louwrina H, Specht Patricia A C, Zanni Emanuele, Bax Carmen, Mik Egbert G, Harms Floor A, Weteringen Willem van, Capelli Laura, Dellacà Raffaele L

СтатьяПеревод в очереди

Аннотация

Sepsis is a severe systemic condition due to an extreme response of the body to an infection. It is responsible for a significant number of deaths worldwide, and is still difficult to diagnose early. In this study, a system was developed for exhaled breath sampling in mechanically ventilated patients at the intensive care unit (ICU), together with a custom-made electronic nose (e-Nose) device for detecting sepsis in exhaled breath. The diagnostic performance of this system was evaluated in an animal sepsis model. Ten pigs (LPS group) were administered lipopolysaccharide (LPS) to induce a systemic inflammatory response. Nine other pigs received a placebo solution (control group). Exhaled breath samples were collected in NalophanTM bags and stored for temperature and humidity equilibration before e-Nose analysis. Measurements were corrected for the effects of different fractions of inspired oxygen (FiO2) on e-Nose sensors. Two classification models using e-Nose and physiological measurements were developed and compared. One hour after LPS administration, the e-Nose data model with FiO2 correction showed a higher accuracy (76.2% (95% confidence interval (CI) [58.0, 94.2])) than the physiological data model (59.0% (95% CI [39.5, 79.5])), indicating the potential of the early detection of sepsis with an e-Nose.

Для цитирования: Robbiani Stefano, Te Nijenhuis Louwrina H, Specht Patricia A C, Zanni Emanuele, Bax Carmen, Mik Egbert G, Harms Floor A, Weteringen Willem van, Capelli Laura, Dellacà Raffaele L. Development of an E-Nose System for the Early Diagnosis of Sepsis During Mechanical Ventilation: A Porcine Feasibility Study.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25113343.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.