MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvoice.2025.01.018

Медицинская библиотека · Journal of voice : official journal of the Voice Foundation · 2025

Severity Cut-Off Ranges for Auditory-Perceptual Evaluation Using Visual Analog Scales.

Walden Patrick R

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This retrospective, observational analytic, cross-sectional research study aimed to establish cut-off scores for categorizing the severity of voice qualities on a 100-unit visual analog scale (VAS). The study investigated the VAS cut-off ranges corresponding to auditory-perceptual ratings of normal, mild, moderate, and severe severities from the GRBAS scale for overall severity, breathiness, roughness, and strain.

METHODS

The study utilized voice samples and ratings from the Perceptual Voice Qualities Database (PVQD). The database contains 296 audio samples, including sustained vowels and sentences, rated by 19 experienced voice clinicians. The raters used a 100-point VAS and the GRBAS scale to evaluate voice qualities. Receiver operator curves (ROC) were calculated to determine cut-off scores for each severity category, balancing a 90% sensitivity with a 10% allowable false-positive categorization.

RESULTS

Cut-off ranges were established for overall severity, breathiness, and roughness, demonstrating similar values across severities. The ranges were: Overall severity: normal (0-15), mild (16-39), moderate (40-69), severe (70-100). Breathiness: normal (0-14), mild (15-34), moderate (35-68), severe (69-100). Roughness: normal (0-13), mild (14-37), moderate (38-65), severe (66-100). For strain, only the normal range (0-15) could be determined with statistical significance.

CONCLUSIONS

This study provided clinically relevant cut-off values for severity categories on a VAS, enhancing communication with patients and facilitating the use of both sensitive and specific categorical measures in voice evaluation. The findings contribute to a more standardized and objective assessment of voice quality.

Для цитирования: Walden Patrick R. Severity Cut-Off Ranges for Auditory-Perceptual Evaluation Using Visual Analog Scales.. Journal of voice : official journal of the Voice Foundation. 2025. DOI: 10.1016/j.jvoice.2025.01.018.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.