Resolution of traumatic vertebral artery dissection and occlusion after repositioning and posterior C1-ring osteosynthesis of a displaced Jefferson burst fracture.
Аннотация
A 70-year-old male sustained a Jefferson burst fracture with unilateral vertebral artery dissection and occlusion by displaced fragments. We performed reduction and posterior C1-ring osteosynthesis. We present a description of the intraoperative manual assessment of atlantoaxial stability. The vertebral artery was found with a good anterograde flow posteroperatively, and MRA showed reperfusion of the vessel. The patient was free of pain with preserved C1-C2 rotation after 6 weeks. Function-preserving posterior C1-ring osteosynthesis after reduction in a displaced Jefferson burst fracture complicated by vertebral artery dissection and occlusion may restore blood flow.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.