Predictive Factor of the Possibility for Aortic Side Branches Coil Embolization during Endovascular Abdominal Aortic Aneurysm Repair.

Aoki Atsushi, Maruta Kazuto, Hosaka Norifumi, Masuda Tomoaki, Omoto Tadashi, Horikawa Yui

СтатьяПеревод в очереди

Аннотация

Objective

Coil embolization of aortic side branches has been additionally performed to prevent type II endoleak during EVAR in our institute. In this study, we evaluated the predictive factors of the possibility for coil embolization of the inferior mesenteric artery (IMA) and lumbar artery (LA) during EVAR.

Methods

Seventy-four EVAR patients during June 2015 and April 2019 were included in the study. The coil embolization procedural time for one vessel is limited to 10 min. Aortic side branches were selected with 4 Fr Shepherd hook type catheter (Medikit, Tokyo, Japan) and were embolized with Interlock (Boston Scientific, MA, USA) via microcatheter. As predictive factors, internal diameter of aortic side branches and the aortic diameter perpendicular to the origin of LA (aortic diameter) were evaluated.

Results

Coil embolization was tried for 52 patent IMAs and all IMAs except two IMAs with ostial stenosis were successfully coil embolized (96.2%). Totally 190 LAs were patent and coil embolization was tried for 144 LAs. Among 144 LAs, 106 LAs (73.6%) were successfully coil embolized and the diameter was significantly longer (2.30±0.51 mm vs. 2.04±0.41 mm, p=0.007) and aortic dimeter was significantly shorter (30.0±8.1 mm vs. 40.5±11.6 mm, p<0.001) in successfully embolized LAs. Cut off value of successful LA coil embolization was 2.06 mm for internal diameter and 36.1 mm for aortic diameter by receiver operating characteristic curve analysis. Successful coil embolization rate for LAs with internal diameter longer than 2.0 mm and aortic diameter less than 36.2 mm was 90% (72 among 80 LAs).

Conclusion

Coil embolization during EVAR for IMA was highly successful, if there was no calcified ostial stenosis. LA embolization was feasible especially for LAs with internal diameter ≥2.0 mm and aortic diameter ≤36.1 mm. This information would be useful to select the target vessel for aortic side branches coil embolization during EVAR. (This is a translation of Jpn J Vasc Surg 2019; 28: 389-396.).

Для цитирования: Aoki Atsushi, Maruta Kazuto, Hosaka Norifumi, Masuda Tomoaki, Omoto Tadashi, Horikawa Yui. Predictive Factor of the Possibility for Aortic Side Branches Coil Embolization during Endovascular Abdominal Aortic Aneurysm Repair.. Annals of vascular diseases. 2020. DOI: 10.3400/avd.oa.20-00115.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.