MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm-2022-1167

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2023

Short-term biological variation of plasma uracil in a Caucasian healthy population.

Winther-Larsen Anne, Madsen Anne Tranberg, Nissen Peter H, Hoffmann-Lücke Elke, Greibe Eva

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Plasma uracil is a new biomarker to assess the activity of dihydropyrimidine dehydrogenase before cancer treatment with fluoropyrimidine drugs. Knowledge on the biological variation of plasma uracil is important to assess the applicability of plasma uracil as a biomarker of drug tolerance and efficacy.

METHODS

A total of 33 apparently healthy individuals were submitted to sequential blood draws for three days. On the second day, blood draws were performed every third hour for 12 h. Plasma uracil was quantified by LC-MS/MS. The within-subject (CVI) and between-subject (CVG) biological variation estimates were calculated using linear mixed-effects models.

RESULTS

The overall median value of plasma uracil was 10.6 ng/mL (range 5.6-23.1 ng/mL). The CVI and CVG were 13.5 and 22.1%, respectively. Plasma uracil remained stable during the day, and there was no day-to-day variation observed. No differences in biological variation components were found between sex and no correlation to age was found. Four samples were calculated to be required to estimate the homeostatic set-point ±15% with 95% confidence.

CONCLUSIONS

Plasma uracil is subject to tight homeostatic regulation without semidiurnal and day-to-day variation, however between-subject variation exists. This emphasizes plasma uracil as a well-suited biomarker for evaluation of dihydropyrimidine dehydrogenase activity, but four samples are required to establish the homeostatic set-point in a patient.

Для цитирования: Winther-Larsen Anne, Madsen Anne Tranberg, Nissen Peter H, Hoffmann-Lücke Elke, Greibe Eva. Short-term biological variation of plasma uracil in a Caucasian healthy population.. Clinical chemistry and laboratory medicine. 2023. DOI: 10.1515/cclm-2022-1167.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.