MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-54960-7

Медицинская библиотека · Scientific reports · 2024

In vivo evaluation of a nanotechnology-based microshunt for filtering glaucoma surgery.

Gniesmer Stefanie, Sonntag Svenja Rebecca, Gapeeva Anna, Cojocaru Ala, Kaps Sören, Adelung Rainer, Sewing Judith, Tura Aysegül, Grisanti Salvatore, Grisanti Swaantje

СтатьяПеревод в очереди

Аннотация

To carry out the preclinical and histological evaluation of a novel nanotechnology-based microshunt for drainage glaucoma surgery. Twelve New Zealand White rabbits were implanted with a novel microshunt and followed up for 6 weeks. The new material composite consists of the silicone polydimethylsiloxane (PDMS) and tetrapodal Zinc Oxide (ZnO-T) nano-/microparticles. The microshunts were inserted ab externo to connect the subconjunctival space with the anterior chamber. Animals were euthanized after 2 and 6 weeks for histological evaluation. Ocular health and implant position were assessed at postoperative days 1, 3, 7 and twice a week thereafter by slit lamp biomicroscopy. Intraocular pressure (IOP) was measured using rebound tonometry. A good tolerability was observed in both short- and medium-term follow-up. Intraocular pressure was reduced following surgery but increased to preoperative levels after 2 weeks. No clinical or histological signs of inflammatory or toxic reactions were seen; the fibrotic encapsulation was barely noticeable after two weeks and very mild after six weeks. The new material composite PDMS/ZnO-T is well tolerated and the associated foreign body fibrotic reaction quite mild. The new microshunt reduces the IOP for 2 weeks. Further research will elucidate a tube-like shape to improve and prolong outflow performance and longer follow-up to exclude medium-term adverse effects.

Для цитирования: Gniesmer Stefanie, Sonntag Svenja Rebecca, Gapeeva Anna, Cojocaru Ala, Kaps Sören, Adelung Rainer, Sewing Judith, Tura Aysegül, Grisanti Salvatore, Grisanti Swaantje. In vivo evaluation of a nanotechnology-based microshunt for filtering glaucoma surgery.. Scientific reports. 2024. DOI: 10.1038/s41598-024-54960-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.