MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/smll.202304941

Медицинская библиотека · Small (Weinheim an der Bergstrasse, Germany) · 2023

Simultaneous Detection of Citric Acid and Oxalic Acid Based on Dual Spectrum and Biomimetic Peroxidase for Urolithiasis Screening with a Fully Automatic Urine Analyzer.

Sun Xianyou, Zhou Shuqi, Zhang Yanchi, Ma Chiyu, Hu Yanjie, Tian Shichao, Wang Xinyi, Kong Liubing, Huang Zhuoru, Liang Tao, Wan Hao, Wang Ping

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Urolithiasis stands as a prevalent ailment within the urinary system, with hyperoxaluria and hypocitraturia being the most frequent manifestations characterized by excessive oxalic acid (OA) and deficient citric acid (CA) levels in urine. Detecting these compounds in urine quantitatively holds paramount importance for early urolithiasis screening. Existing methodologies fall short in achieving simultaneous and on-site identification of OA and CA, posing challenges for accurate urolithiasis screening. Addressing this concern, the study successfully accomplishes the concurrent identification of OA and CA in urine through a combination of dual-spectral analysis and biomimetic peroxidase utilization. Bovine serum albumin and dithiothreitol-modified copper nanoclusters (BSA-DTT-CuNCs) are employed as biomimetic peroxidases, effectively mitigating interference and enabling the simultaneous determination of OA and CA. The quantification range spans from 0 to 12 mm for OA and 0.5 to 2.5 mm for CA, with detection limits of 0.18 and 0.11 mm, respectively. To facilitate swift and on-location urine analysis, a fully automated urine analyzer (FAUA) is introduced that streamlines the process of biomarker pretreatment and identification within urine samples. Validation with real urine samples from urolithiasis patients demonstrates the method's diagnostic precision, highlighting the dual-spectral technique and analyzer's promising role in urolithiasis screening.

Для цитирования: Sun Xianyou, Zhou Shuqi, Zhang Yanchi, Ma Chiyu, Hu Yanjie, Tian Shichao, Wang Xinyi, Kong Liubing, Huang Zhuoru, Liang Tao, Wan Hao, Wang Ping. Simultaneous Detection of Citric Acid and Oxalic Acid Based on Dual Spectrum and Biomimetic Peroxidase for Urolithiasis Screening with a Fully Automatic Urine Analyzer.. Small (Weinheim an der Bergstrasse, Germany). 2023. DOI: 10.1002/smll.202304941.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.