Journal of contemporary brachytherapy · 2023
The application of 3D brachytherapy in cervical stump cancer: A retrospective study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang Chao, Siebert Jason R, Burns Robert, Zheng Yongwei, Mei Ao, Bonacci Benedetta, Wang Demin, Urrutia Raul A, Riese Matthew J, Rao Sridhar, Carlson Karen-Sue, Thakar Monica S, Malarkannan Subramaniam
Аннотация
PURPOSE: Cervical stump cancer is a carcinoma that grows on the cervical stump after a sub-total hysterectomy. There have been no studies on the application of 3D brachytherapy in cervical stump cancer. In the present study, we aimed to compare the curative effects, toxicity, and dosimetry of 3D and 2D brachytherapy in cervical stump cancer.
MATERIAL AND METHODS: Thirty-one patients admitted between 2012 and 2021, who were concurrently treated with intensity-modulated radiation therapy and brachytherapy for cervical stump cancer were divided into three groups according to the brachytherapy techniques: 2D brachytherapy, 3D image-guided brachytherapy (3D-IGBT), and 2D + 3D. For patients undergoing 2D brachytherapy and 3D-IGBT, data on survival, complications, and dose to target area or organs at risk (OARs) were collected and compared. Furthermore, dosimetry difference was investigated by reconstructing the 2D plan into a 3D plan.
RESULTS: The median follow-up duration of all patients was 58 months. The overall 5-year progression-free survival, overall survival, and local control rates were 69.6%, 90.2%, and 78.2%, respectively. Late complications in the rectum, sigmoid colon, and bladder were milder in 3D brachytherapy than in 2D brachytherapy. Concerning the D90 value of clinical target volume (CTV) and D2cm3 value of OARs in EQD2, the 3D brachytherapy provided a lower dose to CTV (76.5 Gy vs. 95.9 Gy, on average) and OARs compared with 2D brachytherapy.
CONCLUSIONS: Despite lacking statistical significance, 3D brachytherapy showed better outcomes regarding late toxicity than 2D brachytherapy, owing to the lower dose coverage in the bladder, rectum, sigmoid colon, and small intestine.
MATERIAL AND METHODS: Thirty-one patients admitted between 2012 and 2021, who were concurrently treated with intensity-modulated radiation therapy and brachytherapy for cervical stump cancer were divided into three groups according to the brachytherapy techniques: 2D brachytherapy, 3D image-guided brachytherapy (3D-IGBT), and 2D + 3D. For patients undergoing 2D brachytherapy and 3D-IGBT, data on survival, complications, and dose to target area or organs at risk (OARs) were collected and compared. Furthermore, dosimetry difference was investigated by reconstructing the 2D plan into a 3D plan.
RESULTS: The median follow-up duration of all patients was 58 months. The overall 5-year progression-free survival, overall survival, and local control rates were 69.6%, 90.2%, and 78.2%, respectively. Late complications in the rectum, sigmoid colon, and bladder were milder in 3D brachytherapy than in 2D brachytherapy. Concerning the D90 value of clinical target volume (CTV) and D2cm3 value of OARs in EQD2, the 3D brachytherapy provided a lower dose to CTV (76.5 Gy vs. 95.9 Gy, on average) and OARs compared with 2D brachytherapy.
CONCLUSIONS: Despite lacking statistical significance, 3D brachytherapy showed better outcomes regarding late toxicity than 2D brachytherapy, owing to the lower dose coverage in the bladder, rectum, sigmoid colon, and small intestine.