MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf03011911

Медицинская библиотека · Canadian journal of anaesthesia = Journal canadien d'anesthesie · 1996

Respiratory depression after low-dose caudal morphine.

Karl H W, Tyler D C, Krane E J

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: To report a case of respiratory depression after a small dose of caudal morphine administered to a 15-mo-old child.

CLINICAL FEATURES: A 15 mo, 9.8 kg boy underwent ureteral reimplantation with general endotracheal anaesthesia and 10 ml bupivacaine 0.25% (2.5 mg.kg-1). Ninety minutes after the bupivacaine, 0.4 mg (1 mg.ml-1, 0.4 ml, 0.04 mg.kg-1) preservative-free morphine was injected after negative aspiration. Slightly more than two hours after caudal morphine, the patient became lethargic and developed decreases in oxygen saturation (to 62%) without change in heart rate or respiratory rate. Intravenous naloxone 0.1 mg (0.01 mg.kg-1) markedly improved his level of consciousness. Racemic epinephrine was administered for treatment of coincident stridor. The patient required 11 hr continuous naloxone infusion (0.001-0.002 mg.kg-1.hr-1) in the intensive care unit. He was discharged on the second postopertive day without further complication.

CONCLUSION

Respiratory depression can occur in children greater than one year of age, even when small doses of caudal morphine are used. Decreased arterial oxygen saturation and lethargy are important heralds. A normal respiratory rate despite substantial hypoxaemia argues that pulse oximetry (without supplemental oxygen where possible) has a clear advantage over impedance pneumography for electronic monitoring.

Для цитирования: Karl H W, Tyler D C, Krane E J. Respiratory depression after low-dose caudal morphine.. Canadian journal of anaesthesia = Journal canadien d'anesthesie. 1996. DOI: 10.1007/bf03011911.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.