Predictive value of dynamic arterial elastance for vasopressor withdrawal: a systematic review and meta-analysis.

Alvarado-Sánchez Jorge Iván, Salazar-Ruiz Sergio, Caicedo-Ruiz Juan Daniel, Diaztagle-Fernández Juan José, Cárdenas-Bolivar Yenny Rocio, Carreño-Hernandez Fredy Leonardo, Mora-Salamanca Andrés Felipe, Montañez-Nariño Andrea Valentina, Stozitzky-Ríos María Valentina, Santacruz-Herrera Carlos, Ospina-Tascón Gustavo Adolfo, Pinsky Michael R

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Dynamic arterial elastance (Eadyn) has been investigated for its ability to predict hypotension during the weaning of vasopressors. Our study focused on assessing Eadyn's performance in the context of critically ill adult patients admitted to the intensive care unit, regardless of diagnosis.

MAIN BODY: Our study was conducted in accordance with the Preferred Reported Items for Systematic Reviews and Meta-Analysis checklist. The protocol was registered in PROSPERO (CRD42023421462) on May 26, 2023. We included prospective observational studies from the MEDLINE and Embase databases through May 2023. Five studies involving 183 patients were included in the quantitative analysis. We extracted data related to patient clinical characteristics, and information about Eadyn measurement methods, results, and norepinephrine dose. Most patients (76%) were diagnosed with septic shock, while the remaining patients required norepinephrine for other reasons. The average pressure responsiveness rate was 36.20%. The synthesized results yielded an area under the curve of 0.85, with a sensitivity of 0.87 (95% CI 0.74-0.93), specificity of 0.76 (95% CI 0.68-0.83), and diagnostic odds ratio of 19.07 (95% CI 8.47-42.92). Subgroup analyses indicated no variations in the Eadyn based on norepinephrine dosage, the Eadyn measurement device, or the Eadyn diagnostic cutoff to predict cessation of vasopressor support.

CONCLUSIONS

Eadyn, evaluated through subgroup analyses, demonstrated good predictive ability for the discontinuation of vasopressor support in critically ill patients.

Для цитирования: Alvarado-Sánchez Jorge Iván, Salazar-Ruiz Sergio, Caicedo-Ruiz Juan Daniel, Diaztagle-Fernández Juan José, Cárdenas-Bolivar Yenny Rocio, Carreño-Hernandez Fredy Leonardo, Mora-Salamanca Andrés Felipe, Montañez-Nariño Andrea Valentina, Stozitzky-Ríos María Valentina, Santacruz-Herrera Carlos, Ospina-Tascón Gustavo Adolfo, Pinsky Michael R. Predictive value of dynamic arterial elastance for vasopressor withdrawal: a systematic review and meta-analysis.. Annals of intensive care. 2024. DOI: 10.1186/s13613-024-01345-8.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.