Milani Alfredo L, Withagen Mariella I J, Vierhout Mark E
Аннотация
INTRODUCTION AND HYPOTHESIS: The objective of this study was to report 1 year anatomical and functional outcomes of trocar-guided total tension-free vaginal mesh (Prolift) repair for post-hysterectomy vaginal vault prolapse with one continuous piece of polypropylene mesh.
METHODS: We conducted a prospective observational cohort study of 46 patients. A minimum sample size of 35 patients was needed to detect a recurrence rate of less than 20% at 12 months. Instruments of measurement used were pelvic organ prolapse quantification and validated questionnaires.
RESULTS: Overall anatomical success was 91% (95% confidence interval 83-99), with significant improvement in experienced bother and quality of life. Mesh exposure occurred in seven patients (15%). No adverse effects on sexual function could be detected.
CONCLUSIONS: Trocar-guided total tension-free vaginal mesh (Prolift) repair with one continuous piece of mesh for post-hysterectomy vaginal vault prolapse is well tolerated and anatomically and functionally highly effective. Results of controlled trials will determine its position in the operative armamentarium.
METHODS: We conducted a prospective observational cohort study of 46 patients. A minimum sample size of 35 patients was needed to detect a recurrence rate of less than 20% at 12 months. Instruments of measurement used were pelvic organ prolapse quantification and validated questionnaires.
RESULTS: Overall anatomical success was 91% (95% confidence interval 83-99), with significant improvement in experienced bother and quality of life. Mesh exposure occurred in seven patients (15%). No adverse effects on sexual function could be detected.
CONCLUSIONS: Trocar-guided total tension-free vaginal mesh (Prolift) repair with one continuous piece of mesh for post-hysterectomy vaginal vault prolapse is well tolerated and anatomically and functionally highly effective. Results of controlled trials will determine its position in the operative armamentarium.