MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/14767058.2015.1067296

Медицинская библиотека · The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2015

Is platelet mass a more significant indicator than platelet count of closure of patent ductus arteriosus?

Demir Nihat, Peker Erdal, Ece İbrahim, Ağengin Kemal, Bulan Keziban Asli, Tuncer Oğuz

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to evaluate whether or not platelet mass contributes to closure of patent ductus arteriosus (PDA) in premature newborns.

STUDY DESIGN AND SUBJECTS: This retrospective study included 115 preterm newborns with hemodynamically significant PDA (hPDA) and 120 newborns without PDA. The newborns' platelet count, mean platelet volume (MPV) and platelet distribution width (PDW) were noted from their files and the platelet mass (platelet count plus MPV/10(3)) was calculated. Patients with congenital abnormality, persistent pulmonary hypertension or sepsis were not included in the study.

RESULTS

Platelet count and PDW were found to not be risk factors for closure of hPDA (p > 0.05), but both high platelet mass (OR 1.25; 95% CI 1.12-1.41) and MPV (OR 1.87; 95% CI 2.52-3.85) were determined to be independent risk factors for hPDA.

CONCLUSIONS

Platelet mass may be a more significant indicator than platelet count of closure of hPDA in preterm newborns.

Для цитирования: Demir Nihat, Peker Erdal, Ece İbrahim, Ağengin Kemal, Bulan Keziban Asli, Tuncer Oğuz. Is platelet mass a more significant indicator than platelet count of closure of patent ductus arteriosus?. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2015. DOI: 10.3109/14767058.2015.1067296.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.