Device Closure of Patent Foramen Ovale After Stroke: Pooled Analysis of Completed Randomized Trials.

СтатьяМетаанализПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kent David M, Dahabreh Issa J, Ruthazer Robin, Furlan Anthony J, Reisman Mark, Carroll John D, Saver Jeffrey L, Smalling Richard W, Jüni Peter, Mattle Heinrich P, Meier Bernhard, Thaler David E

Аннотация

BACKGROUND: The comparative effectiveness of percutaneous closure of patent foramen ovale (PFO) plus medical therapy versus medical therapy alone for cryptogenic stroke is uncertain.

OBJECTIVES: The authors performed the first pooled analysis of individual participant data from completed randomized trials comparing PFO closure versus medical therapy in patients with cryptogenic stroke.

METHODS: The analysis included data on 2 devices (STARFlex [umbrella occluder] [NMT Medical, Inc., Boston, Massachusetts] and Amplatzer PFO Occluder [disc occluder] [AGA Medical/St. Jude Medical, St. Paul, Minnesota]) evaluated in 3 trials. The primary composite outcome was stroke, transient ischemic attack, or death; the secondary outcome was stroke. We used log-rank tests and unadjusted and covariate-adjusted Cox regression models to compare device closure versus medical therapy.

RESULTS: Among 2,303 patients, closure was not significantly associated with the primary composite outcome. The difference became significant after covariate adjustment (hazard ratio [HR]: 0.68; p = 0.049). For the outcome of stroke, all comparisons were statistically significant, with unadjusted and adjusted HRs of 0.58 (p = 0.043) and 0.58 (p = 0.044), respectively. In analyses limited to the 2 disc occluder device trials, the effect of closure was not significant for the composite outcome, but was for the stroke outcome (unadjusted HR: 0.39; p = 0.013). Subgroup analyses did not identify significant heterogeneity of treatment effects. Atrial fibrillation was more common among closure patients.

CONCLUSIONS: Among patients with PFO and cryptogenic stroke, closure reduced recurrent stroke and had a statistically significant effect on the composite of stroke, transient ischemic attack, and death in adjusted but not unadjusted analyses.