Zhonghua yu fang yi xue za zhi [Chinese journal of preventive medicine] · 2025
[Performance evaluation of an acridinium ester-based chemiluminescence assay for heparin-binding protein and its application in the diagnosis of sepsis].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Y Y, Yu S J, Chen Q, Zhan B C, Chen K, Chen G Q, Hong L B, Wu J G
Аннотация
This study aims to comprehensively evaluate the analytical performance and clinical application value of an acridinium ester-based chemiluminescence assay for detecting heparin-binding protein (HBP), providing more accurate laboratory evidence for the early diagnosis of infections and sepsis. The analytical performance of the HBP detection kit based on acridinium ester chemiluminescence was verified in Hangzhou Hospital of Traditional Chinese Medicine in January 2024 to June 2024, including limit of blank (LoB), accuracy, precision, linear range, anti-interference ability, and clinical diagnostic concordance. The potential of this assay in early diagnosis and treatment monitoring of sepsis was assessed. HBP levels were measured in 97 patients with sepsis and 160 healthy controls, and intergroup differences were analyzed using the Mann-Whitney U test. The results showed that the LoB of the HBP detection kit based on acridinium ester chemiluminescence was 0.10 RLU, and low-concentration sample testing showed good discrimination. In the accuracy evaluation, the regression equation between the test reagent and the comparator was y=1.015 2x-2.850 8 (R²=0.995 1). For precision, the CV in intra-assay was ≤3.51%, and the CV in inter-assay was ≤4.18%. Within the linear range of 0.42-493.46 ng/ml, the regression equation was y=0.996 9x+3.066 0 (R²=0.999 1). In interference experiments, the relative deviation was <3%. Clinically, the median HBP concentration in the sepsis group (median: 121.1 ng/ml) was significantly higher than in the control group (median: 6.3 ng/ml, P<0.000 1), with a diagnostic sensitivity of 98.97% and specificity of 96.25%. Age stratification had no effect on HBP levels (U=448,P=0.780 0). In conclusion,the acridinium ester-based chemiluminescence assay requires only about 10 minutes to complete the detection and deliver results, demonstrating acceptable sensitivity, precision, and anti-interference capability. Its wide linear range and rapid detection meet emergency testing needs. Clinical validation confirms HBP's extremely high sensitivity and specificity for sepsis diagnosis, supporting its role as a key marker for early diagnosis, treatment monitoring, and prognosis assessment.