Gastrointestinal endoscopy · 2024
Fixation of the proximal flange of a lumen-apposing metal stent using a through-the-scope endoscopic suturing system to prevent stent migration in single-session EUS-directed transgastric ERCP: a pilot study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Khan Hafiz Muzaffar Akbar, Hussain Azhar, Kumar Vishnu Charan Suresh, Yang Dennis, Hasan Muhammad Khalid
Аннотация
BACKGROUND AND AIMS: With the global obesity pandemic, clinical scenarios requiring urgent ERCP in patients with gastric bypass surgery are on the rise, and single-session EUS-directed transgastric ERCP (SS-EDGE) can effectively address these technical challenges. The aim of this study was to evaluate and describe the safe and effective use of a through-the-scope endoscopic suturing system for anchoring the lumen-apposing metal stents (LAMSs) during SS-EDGE.
METHODS: Six patients with Roux-en-Y gastric bypass (RYGB) underwent SS-EDGE at our center. A through-the-scope endoscopic suturing system was used for anchoring the LAMSs during SS-EDGE.
RESULTS: Clinical and technical success was achieved in all 6 patients without any adverse events related to the procedure. No stent migration, pneumoperitoneum, or GI perforation was noted. At the 4-week follow-up, no stent migration was noted, and the through-the-scope suturing system remained anchored. LAMSs along with tacks were removed, and gastric fistulae were successfully closed endoscopically in all patients to prevent weight gain.
CONCLUSIONS: Use of through-the-scope endoscopic suturing can be a safe, reliable, and potentially cost-effective novel technique for LAMS fixation to successfully perform SS-EDGE in RYGB patients.
METHODS: Six patients with Roux-en-Y gastric bypass (RYGB) underwent SS-EDGE at our center. A through-the-scope endoscopic suturing system was used for anchoring the LAMSs during SS-EDGE.
RESULTS: Clinical and technical success was achieved in all 6 patients without any adverse events related to the procedure. No stent migration, pneumoperitoneum, or GI perforation was noted. At the 4-week follow-up, no stent migration was noted, and the through-the-scope suturing system remained anchored. LAMSs along with tacks were removed, and gastric fistulae were successfully closed endoscopically in all patients to prevent weight gain.
CONCLUSIONS: Use of through-the-scope endoscopic suturing can be a safe, reliable, and potentially cost-effective novel technique for LAMS fixation to successfully perform SS-EDGE in RYGB patients.