MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jps.2600671234

Медицинская библиотека · Journal of pharmaceutical sciences · 1978

Drug contamination of mortars and pestles.

Swinyard E A, Woodhead J H

СтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Evidence is presented suggesting that potent water-insoluble antipentylenetetrazol agents triturated in porcelain mortars and pestles are not removed from this mixing device by the usual laboratory washing procedure. Moreover, amounts sufficient to contaminate the next substance triturated in this vessel can be demonstrated by the subcutaneous pentylenetetrazol seizure threshold test. The data show that a rigorous washing routine must be followed to achieve a "clean" mortar and pestle. Attention is also directed to the importance of using disposable hypodermic syringes, test tubes, etc., whenever possible and of designing an internal control test to determine when implements that must be reused are "clean."

Для цитирования: Swinyard E A, Woodhead J H. Drug contamination of mortars and pestles.. Journal of pharmaceutical sciences. 1978. DOI: 10.1002/jps.2600671234.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.