MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtha.2025.05.030

Медицинская библиотека · Journal of thrombosis and haemostasis : JTH · 2025

Interferences associated with the factor XIa inhibitors asundexian and milvexian in routine and specialized coagulation assays and their removal by activated charcoal-based adsorbents.

Buckley Gavin T, Crowley Maeve P, Harte James V

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Direct inhibition of factor (F)XI/FXIa is emerging as a promising anticoagulant strategy to mitigate the risk of bleeding typically associated with antithrombotic medications, including direct oral anticoagulants (DOACs). While DOACs are known to interfere with a broad range of coagulation assays, the interferences associated with emerging FXIa inhibitors remain incompletely characterized.

OBJECTIVES

This study evaluated the interferences associated with the FXIa inhibitors asundexian and milvexian in a panel of routine and specialized coagulation assays. Additionally, we assessed the capacity of charcoal-based adsorbents-including raw activated charcoal and DOAC-Stop-to remove interferences in coagulometric assays.

METHODS

Human-derived plasma was anticoagulated with increasing concentrations of asundexian or milvexian (0-10 000 ng/mL) and assayed for routine and specialized coagulation parameters before and after treatment with charcoal-based adsorbents using Sysmex CN/CS-series analyzers. Plasma was anticoagulated with both asundexian and milvexian at therapeutic and supratherapeutic concentrations representative of those reported in recent pharmacokinetic trials.

RESULTS

Asundexian and milvexian produced significant dose-dependent interferences in FXIa-dependent coagulation assays, including markedly prolonged activated partial thromboplastin time-based clotting times and markedly reduced intrinsic coagulation factor activities. Treatment with charcoal-based adsorbents effectively removed both asundexian- and milvexian-associated interferences across all affected assays.

CONCLUSION

Emerging FXIa inhibitors interfere significantly with FXIa-dependent coagulation assays, potentially leading to misinterpretation of hemostatic function. However, charcoal-based adsorbents efficiently remove these interferences and enable routine and specialized coagulation testing in the presence of asundexian and milvexian.

Для цитирования: Buckley Gavin T, Crowley Maeve P, Harte James V. Interferences associated with the factor XIa inhibitors asundexian and milvexian in routine and specialized coagulation assays and their removal by activated charcoal-based adsorbents.. Journal of thrombosis and haemostasis : JTH. 2025. DOI: 10.1016/j.jtha.2025.05.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.