MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2024.117042

Медицинская библиотека · Biosensors & bioelectronics · 2024

TE-RPA: One-tube telomerase extension recombinase polymerase amplification-based electrochemical biosensor for precise diagnosis of urothelial carcinoma.

Wang Mengting, Chen Wenzhe, Li Mingzhao, Lin Fuyang, Zhong Jiehui, Ouyang Wenrui, Cai Chao, Zeng Guohua, Liu Hongxing

СтатьяПеревод в очереди

Аннотация

Telomerase demonstrates potential as a non-invasive urinary biomarker for urothelial carcinoma (UC); however, current detection methods are either labor-intensive or exhibit suboptimal performance. There is a need for alternative approaches to enable rapid and early diagnosis of UC. In this study, we propose TE-RPA, which combines telomerase extension (TE) with recombinase polymerase amplification (RPA) for one-tube isothermal amplification. The GC content and length of the telomerase substrate were first considered during the screening process. TE-RPA exponential amplification was initiated by the addition of MgOAc along with a forward primer derived from the products of telomerase-mediated extension and a corresponding reverse primer. The amplification product from TE-RPA was subsequently detected using CRISPR-Cas12a system for trans-cleavage of signal probes on the surface of screen-printed electrode in an electrochemical biosensor, resulting in a current change that reflects the corresponding concentration of telomerase. The TE-RPA/CRISPR-Cas12a/electrochemical sensing platform achieves a limit of detection (LOD) for telomerase activity as low as a single-cell level. In addition, the platform attained an area under the curve (AUC) value of 0.9589 in a clinical evaluation involving urine samples from 43 suspected UC patients. Overall, our proposed platform not only offers an efficient method for telomerase isothermal amplification but also provides a portable and precise diagnostic tool for UC.

Для цитирования: Wang Mengting, Chen Wenzhe, Li Mingzhao, Lin Fuyang, Zhong Jiehui, Ouyang Wenrui, Cai Chao, Zeng Guohua, Liu Hongxing. TE-RPA: One-tube telomerase extension recombinase polymerase amplification-based electrochemical biosensor for precise diagnosis of urothelial carcinoma.. Biosensors & bioelectronics. 2024. DOI: 10.1016/j.bios.2024.117042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.